Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients

نویسندگان

  • Tom Thomaes
  • Martine Thomis
  • Steven Onkelinx
  • Walter Coudyzer
  • Véronique A. Cornelissen
  • Luc Vanhees
چکیده

BACKGROUND The increasing age of coronary artery disease (CAD) patients and the occurrence of sarcopenia in the elderly population accompanied by 'fear of moving' and hospitalization in these patients often results in a substantial loss of skeletal muscle mass and muscle strength. Cardiac rehabilitation can improve exercise tolerance and muscle strength in CAD patients but less data describe eventual morphological muscular changes possibly by more difficult access to imaging techniques. Therefore the aim of this study is to assess and quantify the reliability and validity of an easy applicable method, the ultrasound (US) technique, to measure the diameter of rectus femoris muscle in comparison to the muscle dimensions measured with CT scans. METHODS 45 older CAD patients without cardiac event during the last 9 months were included in this study. 25 patients were tested twice with ultrasound with a two day interval to assess test-retest reliability and 20 patients were tested twice (once with US and once with CT) on the same day to assess the validity of the US technique compared to CT as the gold standard. Isometric and isokinetic muscle testing was performed to test potential zero-order correlations between muscle diameter, muscle volume and muscle force. RESULTS An intraclass correlation coefficient (ICC) of 0.97 ((95%CL: 0.92 - 0.99) was found for the test-retest reliability of US and the ICC computed between US and CT was 0.92 (95%CL: 0.81 - 0.97). The absolute difference between both techniques was 0.01 ± 0.12 cm (p = 0.66) resulting in a typical percentage error of 4.4%. Significant zero-order correlations were found between local muscle volume and muscle diameter assessed with CT (r = 0.67, p = 0.001) and assessed with US (r = 0.49, p < 0.05). Muscle strength parameters were also significantly correlated with muscle diameter assessed with both techniques (range r = 0.45-r = 0.61, p < 0.05). CONCLUSIONS Ultrasound imaging can be used as a valid and reliable measurement tool to assess the rectus femoris muscle diameter in older CAD patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The reliability and validity of ultrasound to quantify muscles in older adults: a systematic review

This review evaluates the reliability and validity of ultrasound to quantify muscles in older adults. The databases PubMed, Cochrane, and Cumulative Index to Nursing and Allied Health Literature were systematically searched for studies. In 17 studies, the reliability (n = 13) and validity (n = 8) of ultrasound to quantify muscles in community-dwelling older adults (≥60 years) or a clinical popu...

متن کامل

Validity and reliability of rectus femoris ultrasound measurements: Comparison of curved-array and linear-array transducers.

Muscle-mass loss augers increased morbidity and mortality in critically ill patients. Muscle-mass loss can be assessed by wide linear-array ultrasound transducers connected to cumbersome, expensive console units. Whether cheaper, hand-carried units equipped with curved-array transducers can be used as alternatives is unknown. Accordingly, our primary aim was to investigate in 15 nondisabled sub...

متن کامل

مقایسه الگوی فعالیت الکترومایوگرافی عضلات دومفصلی زانو بین جوانان و سالمندان در سرعتهای مختلف راه رفتن

Objective: In recent years, it has been focused much attention on gait analysis. Factors such as speed, age and gender affect gait parameters. The purpose of the present study was to compare the electromyographic activity pattern of knee two-joint muscles between younger and older subjects in different gait speeds. Matterials & Methods: The method of current study was analytical cross-sectio...

متن کامل

Interaction of Gender and Body Composition on Rectus Femoris Morphology as Measured With Musculoskeletal Ultrasound Imaging

BACKGROUND Quadriceps function is an important measure in patients recovering postoperatively. Traditionally, strength measures that require high levels of resistance are contraindicated during the early postoperative phase. Thus it may be helpful to evaluate the utilization of other tools, such as ultrasound imaging, that allow for assessment during a position of low resistance. HYPOTHESIS T...

متن کامل

The effect of shoe insole stiffness on electromyography activity pattern of selected lower extremity muscles during running on treadmill

 The purpose of this study was to determine the immediate effect of three types of shoe insoles, on electromyography activity of selected lower extremity muscles during running on treadmill. The electromyography activity of the rectus femoris, vastus lateralis, vastus medialis, biceps femoris, tibialis anterior and gastrocnemius lateralis muscles of 14 male athletes were recorded in non-insole,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012