Detection of Ultra-wide-band Impulsive Noise in a 400 Kv Air Insulated Electricity Substation

نویسندگان

  • Qingshan SHAN
  • P J MOORE
چکیده

A measurement campaign has been carried out in 400kV air insulated electricity substation to characterise and model radio frequency impulsive noise with a view to assessing its impact on wireless network technologies. The relatively recent availability of new technologies such as WiFi, Bluetooth and Zigbee means that particular emphasis has been put on higher frequency bands (e.g. 2.4, 5 GHz) than have previously been investigated. A detection system to measure wideband noise over a spectrum extending up to 5.1 GHz has been designed, implemented and deployed in a large electricity substation in central Scotland. Results based on a preliminary analysis of the recorded data are reported.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mitigation of Transient Overvoltages Generated Due to Switching Operations and Lightning in Gas-insulated Substation (GIS) Without Extra Limiter

Gas-insulated substations (GIS) have different specifications in proportion to air-insulated substations. Transformer failures related to lightning and switching are often reported in the gas insulated substation (GIS). This problem is the voltage magnifications due to reflections of switching and lightning surges at various junctions within the GIS. thereby overvoltages in GIS are more importa...

متن کامل

Impulsive Noise Environment of High Voltage Electricity Transmission Substations and its Impact of the Performance of ZigBee

A measurement system for the characterisation of impulsive noise at frequencies above 700 MHz is presented. The system consists of a pair of ultra-wideband (UWB) quasi-TEM horn antennas, a digital storage oscilloscope and an external hard disk. The particular application of interest is the recording of partial discharge and radiation arising from switching/fault transients in high-voltage elect...

متن کامل

Partial discharge signal detection using ultra high frequency method in high voltage power equipments: a review

Partial discharge (PD) can be detected using ultra high frequency (UHF) method to increase the detection threshold and to improve the performance of on-line measurement of PD in noise environment. The PD emitted energy as electromagnetic emission, acoustic emission and ozone and nitrous oxide gases. We can use this emitted energy to detected PD signal. The best method to detect PD in gas insula...

متن کامل

Low-frequency and Tonal Characteristics of Transformer Noise

Electricity substations and their associated transformers are necessary for community power needs. In NSW these substations are often located in rural areas where background noise is low. Noise ‘hum’ from the transformers can be an issue for residents located nearby to the substation, and the tonal and low-frequency nature of the noise can add to the annoyance. The NSW Industrial Noise Policy a...

متن کامل

Design of an S-band Ultra-low-noise Amplifier with Frequency Band Switching Capability

In this paper, an ultra-low-noise amplifier with frequency band switching capability is designed, simulated and fabricated. The two frequency ranges of this amplifier consist of the 2.4 to 2.5 GHz and 3.1 GHz to 3.15 GHz frequency bands. The designed amplifier has a noise figure of less than 1dB, a minimum gain of 23 dB and a VSWR of less than 2 in the whole frequency band. The design process s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009