Single-control, accident-proof, manometer tap systems.
نویسنده
چکیده
,The need has already been discussed for the careful design of control tap arrangements used in the clinical investigation of intravascular pressures (Hepburn, I967). The risk of accidents has been increased by the considerable number of centres introducing such techniques. Because it was considered ,urgently necessary to reduce these risks, an inexpensive tap system was developed (Hep,burn, I967) using a simple arrangement of standard components. Subsequently the need has been felt for more sophisticated tap systems which are not only simpler in use but which may also be operated in parallel and from a distance. Several designs of single-tap control have bPeen produced (e.g. Cambridge Instrument Co., Carle Instruments, Honeywell Controls, Labotron, and St. Thomas' Hospital, London). Unfortunately these units are expensive and not in general use. Moreover, though they achieve the functional requirements to varying degrees, it has been felt in this department that they could be improved tn safety, simplicity, and convenience. Consejuently an eight-position, click-stop, disctype tap was designed and has recently gained enthusiastic clinical acceptance.
منابع مشابه
Joint fluid pressure in chronic knee effusions.
With sterile precautions and after infiltration with local anaesthetic, a special type of needle was introduced into the lateral aspect of the knee near the upper border of the patella. This needle (S.W.G. 18, Down Bros., with a short bevel and perforations made in the sides 0 5 cm. from the point to prevent blockage) had a tap and a side-arm. A manometer filled with normal saline was attached ...
متن کاملتخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر
Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...
متن کاملThe Application of Systems-Theoretic Accident Model and Process in the Systematic Nonlinear Analysis of Accidents in Car Industry
Background & objectives: Hundreds of methods have been introduced to analyze various events. Hence one of the effective and principle steps in accident analysis is proper and targeted selection of accident analysis method. Traditional methods of accident analysis in complex industries are not comprehensive and examine each components of the system separately. So, the use of new systematic metho...
متن کاملA Combination Simple Manometer and Constant Volume Differential Manometer for Studies in Metabolism
The purpose of this article is to describe a manometer which we have developed during the past year for studies in metabolism and which appears to include a number of features of wide-spread use and interest. It is a combination manometer, offering in a single apparatus the possibilities of either direct or differential manometric measurements. For direct measurements it is the equivalent of tw...
متن کاملStudy on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer
This paper presents comparative study of a new type of manometer calledconcentric tube bulb (C.T.B) manometer. Its performance of measuring differential heightis studied against conventional U-shaped manometer. Pressure drops and mass flow ratesare calculated by taking various systems comprising of different flow measuring devicessuch as orifice and venturimeters using both U- shaped and C.T.B ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 33 2 شماره
صفحات -
تاریخ انتشار 1971