Application of spherical harmonics to image reconstruction for the Compton camera.
نویسندگان
چکیده
The Compton camera can collect SPECT data with high efficiency due to electronic collimation. The data acquired from a Compton camera are projections of source activity along cones and are approximated in this paper by cone-surface integrals. This paper proposes the use of an orthogonal spherical expansion to convert the cone-surface integrals into plane integrals. The conversion technique is efficient. Once the plane integrals are obtained, a 3D image can be reconstructed by the 3D Radon inversion formula. The algorithm is implemented and computer simulations are used to demonstrate the efficiency and accuracy of the proposed reconstruction algorithm.
منابع مشابه
Individual virtual phantom reconstruction for organ dosimetry based on standard available phantoms
Background: In nuclear medicine application often it is required to use computational methods for evaluation of organ absorbed dose. Monte Carlo simulation and phantoms have been used in many works before. The shape, size and volume in organs are varied, and this variation will produce error in dose calculation if no correction is applied. Materials and Methods: A computational framewo...
متن کاملEvaluation of list-mode ordered subset expectation maximization image reconstruction for pixelated solid-state compton gamma camera with large number of channels
The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated solid-state technology for nuclear medicine applications. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (of the order of 106). For Compton camera, especially with a large numbe...
متن کاملReconstruction of cone-beam projections from Compton scattered data
The problem of reconstructing a 3D source distribution from Compton scattered data can be separated into two tasks. First, the angular distribution of line projections at different observation points within the detector volume are reconstructed. Then, reconstruction techniques are applied to the resulting cone-beam projections to synthesize the 3D source distribution. This paper describes an an...
متن کاملList-Mode Maximum Likelihood Reconstruction of Compton Scatter Camera Images in Nuclear Medicine1
A Maximum Likelihood (ML) image reconstruction technique using list-mode data has been applied to Compton scattering camera imaging. List-mode methods are appealing in Compton camera image reconstruction because the total number of data elements in the list (the number of detected photons) is significantly smaller than the number of possible combinations of position and energy measurements, lea...
متن کاملSystem modeling and spatial sampling techniques for simpli cation of transition matrix in 3D Electronically Collimated SPECT
transition matrix in 3D Electronically Collimated SPECT Anne C. Sauve1, Alfred O. Hero1, W. Leslie Rogers2 and Neal H. Clinthorne2 January 15, 1997 Abstract In this paper we will present numerical studies of the performance of a 3D Compton camera being developed at the University of Michigan. We present a physical model of the camera which exploits symmetries and an adapted spatial sampling pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 43 4 شماره
صفحات -
تاریخ انتشار 1998