Ultrasonic tissue characterization of human hypertrophied hearts in vivo with cardiac cycle-dependent variation in integrated backscatter.

نویسندگان

  • T Masuyama
  • F G St Goar
  • T L Tye
  • G Oppenheim
  • I Schnittger
  • R L Popp
چکیده

Integrated ultrasonic backscatter (IB) is a noninvasive measure of the acoustic properties of myocardium. Previous experimental studies have indicated that altered acoustic properties of the myocardium are reflected by the magnitude of variation of IB during the cardiac cycle. In our study, cardiac cycle-dependent variation of IB was noninvasively measured using a quantitative IB imaging system in 12 patients with uncomplicated pressure-overload hypertrophy and 13 patients with hypertrophic cardiomyopathy. Sixteen normal subjects served as a control. The magnitude of cardiac cycle-dependent variation of IB for the posterior wall was 6.0 +/- 0.9 dB in normal subjects, 5.7 +/- 0.8 dB in the patients with uncomplicated pressure-overload hypertrophy, and 6.7 +/- 2.1 dB in the patients with hypertrophic cardiomyopathy. There were no significant differences among any of these groups. In contrast, the magnitude of cardiac cycle-dependent variation of IB for the septum was significantly smaller in the patients with uncomplicated pressure-overload hypertrophy (2.8 +/- 1.3 dB) and in the patients with hypertrophic cardiomyopathy (3.1 +/- 2.3 dB) than in normal subjects (4.9 +/- 1.0 dB). The magnitude of cardiac cycle-dependent variation of IB was smaller as the wall-thickness index increased (r = -0.53, p less than 0.01, n = 82 for all data). This IB measure also correlated with percent-systolic thickening of the myocardium (r = 0.67, p less than 0.01, n = 82). Thus, alteration in the magnitude of cardiac cycle-dependent variation of IB was observed in hypertrophic hearts and showed apparent regional myocardial differences.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DIAGNOSTIC METHODS ULTRASOUND Quantitative ultrasonic tissue characterization with real-time integrated backscatter imaging in normal human subjects and in patients with dilated cardiomyopathy*

We have shown previously that the physical properties of myocardium in dogs can be characterized with quantitative ultrasonic integrated backscatter and that interrogation of the tissue with ultrasound can delineate cardiac cycle-dependent changes in ultrasonic backscatter in normal tissue that disappear with ischemia and reappear with reperfusion if functional integrity is restorable. To deter...

متن کامل

Effects of coronary artery occlusion and reperfusion on cardiac cycle-dependent variation of myocardial ultrasonic backscatter.

We have recently reported a systematic variation in integrated ultrasonic backscatter throughout the cardiac cycle in canine hearts. This study was performed to determine whether the pattern of such variation is modified systematically by ischemia. Measurements of integrated ultrasonic backscatter in selected regions of normal, ischemic, and reperfused hearts were compared in view of known diff...

متن کامل

Estimation of myocardial infarct size with ultrasonic tissue characterization.

BACKGROUND Ultrasonic tissue characterization (UTC) can distinguish normal from infarcted myocardium. Infarcted myocardium shows an increase in integrated backscatter and loss of cardiac cycle-dependent variation in backscatter. The cyclic variation of backscatter is closely related to regional myocardial contractile function; the latter is a marker of myocardial ischemia. The present study was...

متن کامل

Quantitative ultrasonic tissue characterization with real-time integrated backscatter imaging in normal human subjects and in patients with dilated cardiomyopathy.

We have shown previously that the physical properties of myocardium in dogs can be characterized with quantitative ultrasonic integrated backscatter and that interrogation of the tissue with ultrasound can delineate cardiac cycle-dependent changes in ultrasonic backscatter in normal tissue that disappear with ischemia and reappear with reperfusion if functional integrity is restorable. To deter...

متن کامل

Ultrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients.

We have previously shown in studies of experimental animals that myocardium exhibits a cardiac cycle-dependent variation of integrated backscatter that reflects regional myocardial contractile performance and that is blunted promptly after arterial occlusion and recovers after reperfusion. To define the clinical utility of ultrasonic tissue characterization with integrated backscatter for detec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 80 4  شماره 

صفحات  -

تاریخ انتشار 1989