Prevalence, characteristics, and predictors of pulmonary vein narrowing after isolation using the pulmonary vein ablation catheter.
نویسندگان
چکیده
BACKGROUND The risk of pulmonary vein narrowing (PVN) after pulmonary vein isolation, using a novel multi-electrode ablation catheter, is unknown. METHODS AND RESULTS Left atrial volume and PV diameters were compared by computed tomography (CT) before and 3 months after pulmonary vein isolation using duty-cycled phased radio frequency energy (2:1 or 4:1 bipolar/unipolar ratio) in 50 patients. Pulmonary vein diameter was measured in a coronal and axial view at 3 levels (A, ostium; B, 1 cm more distal; C, 2 cm more distal). Moderate PVN was defined as a pulmonary vein diameter reduction of 25 to 50%, and severe PVN as >50%. Left atrial volume decreased by 12±12% (P<0.01). Axial pulmonary vein diameter shortened by a median of 16% (interquartile range [IQR] 28 to 5%), 13% (IQR 25 to 5%), and 9% (IQR 21 to -3%) at level A, B, and C, respectively (P<0.01 for all); coronal pulmonary vein diameter decreased by a median of 16% (IQR 24 to 7%), 11% (IQR 21 to 4%), and 8% (IQR 18 to -2%; P<0.01 for all). Moderate PVN occurred in 30% of the PVs, in 78% of the patients; severe PVN occurred in 4% of the PVs, in 15% of the patients. PV diameter reduction was not related to changes in left atrial volume. CONCLUSIONS Isolation of the pulmonary veins using a multielectrode ablation catheter and duty cycled phased radiofrequency energy delivery results in a consistent moderate reduction of the PV diameters predominantly at the ostium. Severe PVN in 15% of patients raises concerns about the risk for clinical PV stenosis.
منابع مشابه
Evaluation of pulmonary vein stenosis after pulmonary vein isolation using a novel circular mapping and ablation catheter (PVAC).
BACKGROUND Pulmonary vein stenosis (PVST) is a well-known complication of pulmonary vein isolation (PVI). Specific anatomically designed ablation catheters for antral PVI have not been evaluated with regard to the incidence of PVST. We investigated the incidence, severity, and characteristics of PVST after PVI with the Pulmonary Vein Ablation Catheter (PVAC) and phased radiofrequency technology...
متن کاملIncidence and predictors of pulmonary vein stenosis following catheter ablation of atrial fibrillation using the anatomic pulmonary vein ablation approach: results from paired magnetic resonance imaging.
INTRODUCTION There are currently no studies systematically evaluating pulmonary vein (PV) stenosis following catheter ablation of atrial fibrillation (AF) using the anatomic PV ablation approach. METHODS AND RESULTS Forty-one patients with AF underwent anatomic PV ablation under the guidance of a three-dimensional electroanatomic mapping system. Gadolinium-enhanced magnetic resonance (MR) ima...
متن کاملPulmonary vein isolation: comparison of bipolar and unipolar electrograms at successful and unsuccessful ostial ablation sites.
INTRODUCTION No prior studies have quantitatively analyzed the characteristics of bipolar or unipolar electrograms that may be helpful in identifying successful ostial ablation sites in patients with atrial fibrillation undergoing segmental pulmonary vein isolation. METHODS AND RESULTS The characteristics of bipolar and unipolar electrograms recorded at 185 successful and 120 unsuccessful ost...
متن کاملLeft atrial flutter after segmental ostial radiofrequency catheter ablation for pulmonary vein isolation.
Segmental ostial ablation to electrically isolate pulmonary veins has been performed for atrial fibrillation. Left atrial flutter that utilized a critical isthmus adjacent to the ostium of the left superior pulmonary vein was diagnosed and successfully ablated in a patient 3 months after a successful pulmonary vein isolation procedure. Documenting the cause of symptoms after pulmonary vein isol...
متن کاملPulmonary vein stenosis after second-generation cryoballoon ablation for atrial fibrillation
Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF), especially in paroxysmal 1 AF patients. In addition to a radiofrequency ablation catheter, a cryoballoon has been proven as an effective technology in PVI for AF. Recently several randomized trials have shown that cryoballoon ablation was noninferior to radiofrequency ablation with respect to ef...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2012