Adaptive and Intelligent Systems for Generator Monitoring and Protection Purposes

نویسندگان

  • Waldemar Rebizant
  • Janusz Szafran
  • Seung-Jae Lee
  • Sang-Hee Kang
چکیده

New adaptive scheme for signal parameter measurement for generator monitoring and protection is presented. The algorithm is based on the orthogonal components of currents and voltages obtained with adaptive orthogonal filters. The filter data window length and coefficients are adapted according to coarsely estimated signal frequency. As a result, the measurements can be performed with high accuracy in wide frequency band conditions, i.e. also for generator start-up, etc. The measured signals are further used for training of artificial neural networks with the aim to design a robust and effective classifier of generator operation mode. The main attention is paid to the phenomena accompanying pole slipping and out-of-step conditions. Copyright © 2002 IFAC

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fractional order robust adaptive intelligent controller design for fractional-order chaotic systems with unknown input delay, uncertainty and external disturbances

In this paper, a fractional-order robust adaptive intelligent controller (FRAIC) is designed for a class of chaotic fractional order systems with uncertainty, external disturbances and unknown time-varying input time delay. The time delay is considered both constant and time varying. Due to changes in the equilibrium point, adaptive control is used to update the system's momentary information a...

متن کامل

Adaptive Protection Based on Intelligent Distribution Networks with the Help of Network Factorization in the Presence of Distributed Generation Resources

Factorizing a system is one of the best ways to make a system intelligent. Factorizing the protection system, providing the right connecting agents, and transmitting the information faster and more reliably can improve the performance of a protection system and maintain system reliability against distributed generation resources. This study presents a new method for coordinating network protect...

متن کامل

Intelligent Control for the Variable-Speed Variable-Pitch Wind Energy System

In this paper, a new type of multi-variable compensation control method for the wind energy conversion systems (WECS) is presented. Based on wind energy conversion systems, combining artificial neural network (ANN) control and PID, a new type of PID NN intelligent controller for steady state torque of the wind generator is designed, by which the steady state torque output is regulated to track ...

متن کامل

Online Voltage Stability Monitoring and Prediction by Using Support Vector Machine Considering Overcurrent Protection for Transmission Lines

In this paper, a novel method is proposed to monitor the power system voltage stability using Support Vector Machine (SVM) by implementing real-time data received from the Wide Area Measurement System (WAMS). In this study, the effects of the protection schemes on the voltage magnitude of the buses are considered while they have not been investigated in previous researches. Considering overcurr...

متن کامل

Impedance-Based Out-of-Step Protection of Generator in the Presence of STATCOM

This paper presents a novel impedance-based approach for out-of-step (OOS) protection of a synchronous generator. The most popular and commonly used approaches for detecting OOS conditions are based on the measurement of positive sequence impedance at relay location. However, FACTS devices change the measured impedance value and thus disrupt the performance of impedance-based relay function. In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002