The value of chest CT for prediction of breast tumor size: comparison with pathology measurement
نویسندگان
چکیده
BACKGROUND Little information is available on the use of chest computed tomography (CT) to predict breast tumor size in breast cancer, despite the fact that chest CT examinations are being increasingly used. The purpose of this study was to evaluate the value of chest CT for predicting breast tumor size using pathology measurements as reference standards. METHODS Tumor sizes (defined as greatest diameter) were retrospectively measured on the preoperative chest CT images of 285 patients with surgically proven unifocal, invasive breast carcinoma. Greatest tumor diameters as determined by chest CT and pathologic examinations were compared by linear regression and Spearman's rho correlation analysis. Concordance between CT and pathology results was defined as a diameter difference of <5 mm. Subgroup analyses were also performed with respect to tumor size (<20 mm or ≥20 mm) and histological subtype (invasive ductal carcinoma(IDC) or non-IDC). RESULTS CT and pathology measured diameters were found to be linearly related (size at pathology = 1.086 × CT determined tumor size - 1.141; Spearman's rho correlation coefficient = 0.84, P<0.001). Most tumors (n = 228, 80.0%) were concordant by chest CT and pathology, but 36 tumors (12.7%) were underestimated by CT (average underestimation, 11 mm; range, 6-36 mm) and 21 tumors (7.4%) were overestimated (average overestimation by CT, 10 mm; range, 6-19 mm). The concordance rate between the two sets of measurements was greater for tumor of <20 mm and for IDC (P<0.001 and P = 0.011, respectively). CONCLUSIONS Tumor size by chest CT is well correlated with pathology determined tumor size in breast cancer patients, and the diameters of the majority of tumors by chest CT and pathology differed by <5 mm. In addition, the concordance rate was higher for breast tumors of <20 mm and for tumors of the IDC histologic subtype.
منابع مشابه
Comparing X-ray dose reduction capability of silicon-bismuth micro- and nanocomposite shields using chest CT test
Comparison of radiation shields of different thicknesses and structures (especially different particle sizes of their constituents) is helpful to select an appropriate shield for patient protection in medical imaging tests particularly CT-scan. In this study micro- and nano-powders of bismuth were mixed with silicone matrix to make composite radiation shields for breast. The shields were provid...
متن کاملMeasurement of organ dose in chest CT examination using Monte Carlo simulation
Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...
متن کاملDiagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...
متن کاملIs there a difference in FDG PET findings of invasive ductal carcinoma of the breast with and without coexisting DCIS?
Objective(s): Studies have reported that invasive ductal carcinoma (IDC) with coexisting ductal carcinoma in situ (DCIS) show lower metastatic potential and recurrence and better overall survival than pure IDC. In this study, we assessed F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) imagesof patients with newly diagnosed IDC to...
متن کاملUsefulness of nanoparticles to making shield and protection of sensitive organs in chest CT scan test
Introduction: Recently, the use of nanoparticles has increased for many purpose in medicine. One of these is using the nano particles in shields structure to protect sensitive organs such as breast which placed inside the field of chest CT scan and receives high dose. The aim of this study was the use of nano Bi2O3 to making shield for protection breast in chest CT examination ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2013