Coil type does not affect angiographic follow-up outcomes of cerebral aneurysm coiling: a systematic review and meta-analysis.

نویسندگان

  • I Rezek
  • G Mousan
  • Z Wang
  • M H Murad
  • D F Kallmes
چکیده

BACKGROUND AND PURPOSE Previous studies varied in their conclusions about the superiority of second-generation coils compared with bare platinum. In this systematic review and meta-analysis, we assessed differences in reported unfavorable angiographic outcomes of cerebral aneurysms treated with coil embolization as a function of coil type. MATERIALS AND METHODS This systematic review covered 1999-2011 through the use of Ovid MEDLINE and EMBASE. Search terms were "subarachnoid hemorrhage," "intracranial aneurysms," "endovascular treatment," and "coiling." Inclusion criteria were studies reporting >50 aneurysms with imaging follow-up. We defined "unfavorable angiographic outcome" as either "recanalization," <90% occlusion, or "incomplete occlusion" at follow-up. Rates of unfavorable outcomes were pooled through the use of random effects models and compared across various coil types. Multivariate random effects meta-regression models were used to further explore the differences in outcomes related to coil type. RESULTS We included 82 studies, comprising 90 patient cohorts, among which, 65 (72%) used bare platinum coils, 8 (8.9%) used Matrix, 11 (12%) used HydroCoil, and 6 (6.7%) used Cerecyte. The overall unfavorable outcome rate was 19% (95% CI: 17%,21%). Unfavorable outcome rates were 20% (95% CI: 17%, 22%) for bare platinum coils, 23% (95% CI: 16%, 29%) for Matrix, 15% (95% CI: 9%, 21%) for HydroCoil, and 15% (95% CI: 7%, 23%) for Cerecyte, respectively. The difference in unfavorable outcome rates among the various coil types was not statistically significant after adjusting for baseline characteristics, including aneurysm size, rupture status, and follow-up duration. CONCLUSIONS The rate of unfavorable angiographic outcomes was not statistically different across the major approved coil types. The quality of the evidence, however, remains low because of high heterogeneity, small sample size, and potential publication bias.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of core laboratory and multiple-reader interpretation of angiographic images on follow-up outcomes of coiled cerebral aneurysms: a systematic review and meta-analysis.

BACKGROUND AND PURPOSE Reported rates of recanalization following coil embolization vary widely across studies. Some confounders are known to affect outcomes but others remain questionable. In the current study, we assess differences in reported angiographic outcomes for cerebral aneurysms treated with coil embolization as a function of single vs multiple readers and site investigator vs core l...

متن کامل

Coiling of very large or giant cerebral aneurysms: long-term clinical and serial angiographic results.

BACKGROUND AND PURPOSE Initial complete occlusion of very large or giant aneurysms often cannot be accomplished, and most will partially reopen over time. This study was performed to assess the clinical and angiographic outcome of patients with very large or giant cerebral aneurysms treated with detachable coils. METHODS During 6 years, 29 patients with 31 very large or giant (20-55-mm) cereb...

متن کامل

Comparison of Stent-Assisted Coil Placement and Coiling-Only for the Treatment of Ruptured Intracranial Aneurysms

BACKGROUND The use of a stent during the acute post-hemorrhage period is controversial. We conducted a retrospective analysis on the clinical and angiographic outcomes of the ruptured aneurysms that were embolized with stent-assisted coiling or coiling-only. MATERIAL AND METHODS We reviewed data of 279 patients with 279 ruptured intracranial aneurysms who underwent coil embolization between Jul...

متن کامل

Coil embolization in 481 ruptured intracranial aneurysms: angiographic and clinical results.

PURPOSE We aimed to report our 13-year experience with the embolization of ruptured cerebral aneurysms using detachable coils and postembolization angiographic and clinical results. MATERIALS AND METHODS Between June 1998 and September 2011, 481 patients with ruptured aneurysms were referred for endovascular treatment with detachable coils at our center. The technical feasibility, procedural ...

متن کامل

Endovascular Treatment of Very Small Intracranial Aneurysms: Meta-Analysis.

BACKGROUND AND PURPOSE Outcomes of endovascular treatment of very small intracranial aneurysms are still not well-characterized. Recently, several series assessing coil embolization of tiny aneurysms have presented new promising results. Thus, we performed a systematic review and meta-analysis of studies evaluating endovascular treatment of very small intracranial aneurysms. MATERIALS AND MET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 34 9  شماره 

صفحات  -

تاریخ انتشار 2013