Construction of Finite Element Model for an Artificial Atlanto-Odontoid Joint Replacement and Analysis of Its Biomechanical Properties.

نویسندگان

  • Yong Hu
  • Wei-Xin Dong
  • Shannon Hann
  • Zhen-Shan Yuan
  • Xiao-Yang Sun
  • Hui Xie
  • Meichao Zhang
چکیده

AIM To investigate the stress distribution on artificial atlantoaxial-odontoid joint (AAOJ) components during flexion, extension, lateral bending and rotation of AAOJ model constructed with the finite element (FE) method. MATERIAL AND METHODS Human cadaver specimens of normal AAOJ were CT scanned with 1 mm -thickness and transferred into Mimics software to reconstruct the three-dimensional models of AAOJ. These data were imported into Freeform software to place a AAOJ into a atlantoaxial model. With Ansys software, a geometric model of AAOJ was built. Perpendicular downward pressure of 40 N was applied to simulate gravity of a skull, then 1.53 N• m torque was exerted separately to simulate the range of motion of the model. RESULTS An FE model of atlantoaxial joint after AAOJ replacement was constructed with a total of 103 053 units and 26 324 nodes. In flexion, extension, right lateral bending and right rotation, the AAOJ displacement was 1.109 mm, 3.31 mm, 0.528 mm, and 9.678 mm, respectively, and the range of motion was 1.6°, 5.1°, 4.6° and 22°. CONCLUSION During all ROM, stress distribution of atlas-axis changed after AAOJ replacement indicating that AAOJ can offload stress. The stress distribution in the AAOJ can be successfully analyzed with the FE method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Evaluation and Comparison of the Artificial and Natural Skin Properties Using Finite Element Method

Introduction: The self-repair process cannot occur in the skin lesions, therefore, skin replacements are used due to the formation of a scar, which resulted in the complete loss of skin. Artificial skin should have the same specifications as the natural skin. The finite element methods were used in this study to evaluate the biomechanichal properties of natural and artificial skins. Materials ...

متن کامل

Design of an Elastic Arthroplastic Disc Optimized under Different Loads

Introduction: Due to limitations of current treatments for degenerative disc disease, arthroplastic methods to repair the diseased disc have been proposed. The artificial disc is a mobile implant for degenerative disc replacement that attempts to lessen the degeneration of the adjacent elements following interbody fusion procedures. Because the success of artificial disc replacement depends on ...

متن کامل

A Comparison Study on Various Finite Element Models of Riveted Lap Joint by the Use of Dynamic Model Updating

Till now, various models have been proposed in literature to simulate the behavior of riveted structures. In order to find the most accurate analytical method in modeling the dynamic behavior of riveted structures, a comparison study is performed on several of these models, in this research. For this purpose, experimental modal analysis tests are conducted on a riveted plate to verify the effic...

متن کامل

Updating finite element model using frequency domain decomposition method and bees algorithm

The following study deals with the updating the finite element model of structures using the operational modal analysis. The updating process uses an evolutionary optimization algorithm, namely bees algorithm which applies instinctive behavior of honeybees for finding food sources. To determine the uncertain updated parameters such as geometry and material properties of the structure, local and...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Turkish neurosurgery

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 2016