Measurement precision in a series of visual fields acquired by the standard and fast versions of the Swedish interactive thresholding algorithm: analysis of large-scale data from clinics.
نویسندگان
چکیده
IMPORTANCE Swedish Interactive Thresholding Algorithm (SITA) testing strategies for the Humphrey Field Analyzer have become a clinical standard. Measurements from SITA Fast are thought to be more variable than SITA Standard, yet some clinics routinely use SITA Fast because it is quicker. OBJECTIVE To examine the measurement precision of the 2 SITA strategies across a range of sensitivities using a large number of visual field (VF) series from 4 glaucoma clinics in England. DESIGN, SETTING, AND PARTICIPANTS Retrospective cohort study at Moorfields Eye Hospital in London, England; Gloucestershire Eye Unit at Cheltenham General Hospital; Queen Alexandra Hospital in Portsmouth, England; and the Calderdale and Huddersfield National Health Service Foundation Trust that included 66,974 Humphrey 24-2 SITA Standard VFs (10,124 eyes) and 19,819 Humphrey 24-2 SITA Fast VFs (3654 eyes) recorded between May 20, 1997, and September 20, 2012. Pointwise ordinary least squares linear regression of measured sensitivity over time was conducted using VF series of 1 random eye from each patient. Residuals from the regression were pooled according to fitted sensitivities. For each sensitivity (decibel) level, the standard deviation of the residuals was used to estimate measurement precision and were compared for SITA Standard and SITA Fast. Simulations of progression from different VF baselines were used to evaluate how different levels of precision would affect time to detect VF progression. MAIN OUTCOME AND MEASURE Median years required to detect progression. RESULTS Median (interquartile range) patient age, follow-up, and series lengths for SITA Standard were 64 (53-72) years, 6.0 (4.0-8.5) years, and 6 (4-8) VFs, respectively; for SITA Fast, medians (interquartile range) were 70 (61-78) years, 5.1 (3.2-7.3) years, and 5 (4-6) VFs. Measurement precision worsened as sensitivity decreased for both test strategies. In the 20 to 5 dB range, SITA Fast was less precise than SITA Standard; this difference was largest between 15 to 10 dB, where variability in both methods peaked. Translated to median time to detection, differences in measurement precision were negligible, suggesting minimal effects on time to detect progression. CONCLUSIONS AND RELEVANCE Although SITA Standard is a more precise testing algorithm than SITA Fast at lower VF sensitivities, it is unlikely to make a sizeable difference to improving the time to detect VF progression.
منابع مشابه
Pervasive white and colored noise removing from magnetotelluric time series
Magnetotellurics is an exploration method which is based on measurement of natural electric and magnetic fields of the Earth and is increasingly used in geological applications, petroleum industry, geothermal sources detection and crust and lithosphere studies. In this work, discrete wavelet transform of magnetotelluric signals was performed. Discrete wavelet transform decomposes signals into c...
متن کاملMeasurement of Choroidal Neovascular Area in Age-Related Macular Degeneration using Modified Otsu’s Thresholding Method
Introduction: Age-related Macular Degeneration (AMD) is one of the most important causes of irreversible blindness in the developed world and prevents the affected person from performing simple tasks such as reading, driving and facial recognition. In the AMD, new blood vessels grow underneath the retina in a process called choroidal neovascularisation (CNV). There ...
متن کاملI-18: Evaluating Pregnancy and Long-Term Outcomes of ART
When treating infertile couples by assisted reproductive technologies (ART), all aspects of their care in individual clinics should be evaluated frequently. Results should then be compared with other clinics offering similar treatment. Evaluation of possible adverse longterm outcomes can be achieved by pooling results from individual clinics in national, regional and international registers and...
متن کاملImproved prediction of blast-induced vibrations in limestone mines using Genetic Algorithm
Like most limestone mines, which produce the raw materials required for cement companies, the transportation cost of the raw materials used in the Shahrood Cement Company is high. It has been tried to build the crushing and grinding plant close to the mine as much as possible. On the other hand, blasting has harmful effects, and the impacts of blast-induced damages on the sensitive machinery, e...
متن کاملRobust state estimation in power systems using pre-filtering measurement data
State estimation is the foundation of any control and decision making in power networks. The first requirement for a secure network is a precise and safe state estimator in order to make decisions based on accurate knowledge of the network status. This paper introduces a new estimator which is able to detect bad data with few calculations without need for repetitions and estimation residual cal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JAMA ophthalmology
دوره 133 1 شماره
صفحات -
تاریخ انتشار 2015