Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements

نویسندگان

  • Natalia M. Martinho
  • Joseane Marques
  • Valéria R. Silva
  • Silvia L. A. Silva
  • Leonardo C. Carvalho
  • Simone Botelho
چکیده

OBJECTIVE The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM) dynamometric measurements for maximum and average strengths, as well as endurance. METHOD A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4 ± 3.9) participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC) was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS The intra and inter-raters' analyses showed good reliability for maximum strength (ICC(intra-rater1)=0.96, ICC(intra-rater2)=0.95, and ICC(inter-rater)=0.96), average strength (ICC(intra-rater1)=0.96, ICCi(ntra-rater2)=0.94, and ICC(inter-rater)=0.97), and endurance (ICC(intra-rater1)=0.88, ICC(intra-rater2)=0.86, and ICC(inter-rater)=0.92) dynamometric measurements. CONCLUSIONS The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of pelvic floor muscle strength assessment in healthy continent women

BACKGROUND The aim of this study was to compare pelvic floor muscle (PFM) strength using transvaginal digital palpation in healthy continent women in different age groups, and to compare the inter- and intra-rater reliability of examiners performing anterior and posterior vaginal assessments. METHODS We prospectively studied 150 healthy multiparous women. They were distributed into four diffe...

متن کامل

Reliability and validity of the Medical Research Council (MRC) scale and a modified scale for testing muscle strength in patients with radial palsy.

OBJECTIVE To assess the inter-rater and intra-rater reliability and validity of the original and a modified Medical Research Council scale for testing muscle strength in radial palsy. DESIGN Prospective, randomized validation study. PATIENTS Thirty-one patients with peripheral paresis of radial innervated forearm muscles were included. METHODS Wrist extension, finger extension and grip st...

متن کامل

Intra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy

Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...

متن کامل

Reliability of superficial male pelvic floor structural measurements using linear-array transperineal sonography.

This study evaluated reliability of measures for superficial structures of the male pelvic floor (PF) obtained via transperineal sonography. Two embalmed cadavers were dissected to identify positioning of muscles on and around the bulb of the penis and to confirm the PF protocol. Cross-sectional area (CSA) and linear thickness of the bulb of the penis, urethra, bulbospongiosus (BS) muscles, and...

متن کامل

Investigation of transabdominal real-time ultrasound to visualise the muscles of the pelvic floor.

Clinical measurement of pelvic floor muscle activity commonly involves techniques that are both physically and psychologically invasive. This study investigated transabdominal application of ultrasound to measure pelvic floor muscle action. The specific aims were to establish the face validity of ultrasound measures of displacement of the posterior bladder wall as a reflection of pelvic floor m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2015