Comparison of the GlideScope and the McGrath method using vascular forceps and a tube exchanger in cases of simulated difficult airway intubation.

نویسندگان

  • Jae-Hang Shim
  • Woo Jae Jeon
  • Sang Yun Cho
  • Gyu Ho Choe
چکیده

BACKGROUND A "difficult airway" can be simulated with an extrication collar, which restricts cervical motion and mouth opening. The purpose of this study is to compare the efficacy of the GlideScope and the McGrath in difficult airway simulation. METHODS Patients were randomized using computer-generated numbers and were placed into the GlideScope group or the McGrath group. The total intubation time was defined as the time measured from when the anesthesiologist picks up the device to the time at which three successive end-tidal CO2 values are acquired after intubation. RESULTS There was no significant difference in total intubation time between the two groups (73.0 ± 25.3 sec vs. 72.3 ± 20.9 sec, P = 0.92). The success rates of the first intubation attempt did not differ between the two groups (82.8% vs. 83.3%, P = 0.95). CONCLUSIONS Our results suggest that there are no significant differences in the intubations with GlideScope and McGrath using vascular forceps and tube exchangers in difficult intubation scenarios.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A good laryngeal view does not guarantee perfectly successful tracheal intubation

tracheal intubation is the most common factor related to serious airway complications during anesthesia [1]. Difficult tracheal intubation is defined as insertion of the endo-tracheal tube using direct laryngoscopy that requires more than two attempts lasting more than 10 min each or that requires an alternative technique [2]. The difficult airway involves interactions among patient factors, th...

متن کامل

Randomized comparison of the effectiveness of nasal intubation using a GlideScope video laryngoscope with Magill forceps versus vascular forceps in patients with a normal airway

PURPOSE The GlideScope® video laryngoscope (GVL) is widely used for nasotracheal intubation in dental and facial plastic surgery. The angle of the Magill forceps is different from that of the GVL blade, which suggests that the Magill forceps are not the ideal forceps for use with the GVL. The purpose of this study was to compare the effectiveness of the Magill forceps vs vascular forceps for na...

متن کامل

Methods to Improve Success With the GlideScope Video Laryngoscope.

Occasionally intubation of patients is difficult using a video laryngoscope (GlideScope, Verathon Medical) because of an inability to guide the endotracheal tube to the glottis or pass the tube into the trachea despite an adequate view of the glottis. We examined methods to improve success when this difficulty occurs. A literature search revealed 253 potential sources, with 25 meeting search cr...

متن کامل

Comparison of the Incidence of Sore Throat and Hemodynamic Changes in ‎Airway Management by Macintosh, Glideoscope Laryngoscope and ‎Laryngeal Mask Airway Techniques: Randomized Controlled Trial

Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway  techniques in elective surg...

متن کامل

Comparison between Glidescope and Lightwand for tracheal intubation in patients with a simulated difficult airway

BACKGROUND Although Lightwand and Glidescope have both shown high success rates for intubation, there has been no confirmation as to which device is most effective for difficult endotracheal intubation. We compared the Glidescope and Lightwand devices in terms of duration of intubation and success rate at the first attempt in a simulated difficult airway situation. METHODS Fifty-eight patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Korean journal of anesthesiology

دوره 69 2  شماره 

صفحات  -

تاریخ انتشار 2016