Pre-operative Evaluation of Eustachian Tube Function Using a Modified Pressure Equilibration Test is Predictive of Good Postoperative Hearing and Middle Ear Aeration in Type 1 Tympanoplasty Patients

نویسندگان

  • Seung Hyo Choi
  • Ju Hee Han
  • Jong Woo Chung
چکیده

OBJECTIVES The Eustachian tube (ET) plays an important role in maintaining a normally aerated middle ear. Inflammation in middle ear disease is related to ET dysfunction, and postoperative restoration of middle ear integrity and hearing are closely related to ET function in chronic ear disease patients. After successful tympanoplasty, restoration of a well-aerated middle ear with good ET function can permit better compliance of the tympanic membrane. In this study, we evaluated the predictive validity of preoperative ET function measurements. METHODS We reviewed 137 patients who underwent type 1 tympanoplasty. All patients had non-cholesteatomatous chronic otitis media and received canal wall-up-type tympanomastoidectomies. Patients were categorized into four groups according to preoperative ET function measurements using a modified pressure inflation-deflation equilibration test. Group I patients had residual pressures less than 10 daPa, and Group IV patients showed no pressure change (poor results). Groups II and III were intermediate. Hearing levels were determined using pure tone averages at four frequencies. Postoperative tympanography was performed to determine middle ear aeration. RESULTS The preoperative air bone (AB) gap was 29.6+/-7.0 dB, and the postoperative gap was 16.5+/-5.7 dB; thus, there was significant overall improvement. In all groups, hearing was significantly better after surgery, but the worst postoperative hearing level was seen in Group IV patients. Type B tympanograms were more frequently recorded in Group IV patients than they were in Group I or II patients. Postoperative AB gaps were 9.2+/-3.8 dB in patients with type A tympanograms, 13.4+/-2.1 dB in those with type As, 24.1+/-2.5 dB in those with type C, and 18.5+/-2.8 dB in those with type B. CONCLUSION ET function measured with a modified pressure equilibration test using an inflation-deflation manometric method is a good indicator of an aerated middle ear and is predictive of improved postoperative hearing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pediatric tympanoplasty: effect of contralateral ear status on outcomes.

OBJECTIVE To assess the prognostic value of different variables on the outcome of pediatric type I tympanoplasty. DESIGN Retrospective review of medical records. SETTING An otolaryngology department in a large urban tertiary care medical center. PATIENTS We reviewed 72 ears in 60 patients who had undergone a type I tympanoplasty from 1987 to 2000. Patient ages ranged from 3 to 18 years. ...

متن کامل

PREVALENCE OF TRAUMATIC TYMPANIC MEMBRANE PERFORATION IN PATIENTS WITH A PATULOUS EUSTACHIAN TUBE

Background: With respect to physical relations in force and pressure, we hypothesized that the prevalence of traumatic tympanic membrane perforation in patients with a patulous Eustachian tube is greater than normal, because in Eustachian tube patency, the internal air pressure of the middle ear will not increase after compression, subsequent to trauma. Therefore the force upon the tympanic...

متن کامل

[Evaluation of tympanometric alterations in patients subject to general anesthesia with nitrous oxide].

UNLABELLED The nitrous oxide is an inhaling gas that can increase intratympanic pressure during the anesthetic act and cause negative pressure after it is discontinued, mainly in patients with Eustachian tube dysfunction. These pressure variations may come up with clinical implications such as tympanic membrane rupture, ossicular system disarticulation, haemotympanum, barotraumas, prosthesis di...

متن کامل

Balloon dilation of the eustachian tube: a tympanometric outcomes analysis

BACKGROUND Eustachian tube dysfunction (ETD) is a common medical issue, occurring in at least 1% of the adult population. Patients suffering from ET dysfunction typically present with complaints of hearing loss or sensation of pressure or plugged ear, which can lead to impaired quality of life. Over time ETD can result in conductive hearing loss or choleastatoma formation. Effective theraputic ...

متن کامل

Role of Impedance Audiometry in Evaluation of Eustachian Tube Function and Its Correlation with Tympanoplasty Surgery Outcome: Our Experience

Background: Normal Eustachian tube function is one of the important factor required for successful tympanoplasty outcome. A clinically useful test for assessment of Eustachian tube function is still lacking. Aims And Objectives: To evaluate Eustachian tube function by impedance audiometry and compare the outcome of surgery with respect to graft take up in normal and abnormal Eustachian tube fun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2009