Thermal analysis of vapour compression refrigeration system with R152a and its blends R429A, R430A, R431A and R435A

نویسندگان

  • A. Baskaran
  • P. Koshy Mathews
چکیده

This paper presents the analysis results of R429A, R430A, R431A and R435A as drop in substitute for R152a at various evaporating temperature with condenser temperature 30°C, 40°C and 50°C. A theoretical study of thermodynamic properties such as pressure, density, and specific volume, latent heat of vaporization compression index, and critical values are done. The theoretical performance of vapour compression refrigeration system with R152a, R429A, R430A, R431A and R435A was done and their results are compared. The effects of the main parameters of performance analysis such as refrigerating effect, compressor work, coefficient of performance, volumetric refrigerating capacity, discharge temperature, pressure ratio, condenser duty, compressor power, refrigerating mass flow are analyzed for various evaporating temperatures. The compressor power required for the refrigeration during analysis with R152a and its blends were observed. The results shows that the refrigerants R435A consumes 1.098% less compressor power than that of R152a.The COP, Refrigerating effect for R435A is 1.229%,32.198% higher than R152a respectively . The refrigerant mass flow is decreased by 24.353% while using R435A substitute to R152a. Other results obtained in the analysis show a positive indication of using R435A as refrigerant in vapour compression refrigeration system substitute to R152a. Index Terms —R152a, R429A, R430A, R431A, R435A, vapour compression Refrigeration ——————————  ——————————

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Performance comparison of vapour compression refrigeration system using various alternative refrigerants

A performance analysis on a vapour compression refrigeration system with various refrigerants mixture of R152a, RE170, R600a, and R290 were done for various mixture ratios and their results were compared with R134a as possible alternative replacement. The results showed that all of the alternative refrigerants investigated in the analysis except R431A, [R 152a (29%), R290 (71%)] have a slightly...

متن کامل

Methods for Improving Exergetic Efficiency of Multi-evaporators Single Compressor and Single Expansion Valve in Vapour Compression Refrigeration Systems Using Thirteen Ecofriendly Refrigerants for Reducing Global Warming and Ozone Depletion

The methods for improving second law efficiency have been considered in this paper by using liquid vapour heat exchanger is investigated in this paper. Detailed energy and exergy analysis of multi-evaporators at different temperatures with single compressor and single expansion valve using liquid vapour heat exchanger vapour compression refrigeration systems have been done in terms of performan...

متن کامل

Various Approaches to Thermodynamic Optimization of a Hybrid Multi-effect Evaporation with Thermal Vapour Compression and Reverse Osmosis Desalination System Integrated to a Gas Turbine Power Plant

This paper investigates the simulation of a hybrid desalination system composed of multi-effect evaporation with thermal vapour compression desalination (METVC) and reverse osmosis (RO) plant. The hybrid desalination system is also integrated with a gas turbine power plant through a heat recovery steam generator (HRSG). First, a comprehensive Thermodynamic model for HRSG, METVC, and RO are deve...

متن کامل

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

A performance analysis on a vapour compression refrigeration system with various eco-friendly refrigerants of HFC152a, HFC32, HC290, HC1270, HC600a and RE170 were done and their results were compared with R134a as possible alternative replacement. The results showed that the alternative refrigerants investigated in the analysis RE170, R152a and R600a have a slightly higher performance coefficie...

متن کامل

Combined Refrigeration Cycle for Thermal Power Plant Using Low Grade Waste Steam

Now a days, In most of the thermal power plant, where low-pressure steam is being exhausted to the atmosphere as a waste steam. This waste heat could be use to operate many small preheating or cooling equipments or small scale plants. There are many refrigeration systems present for refrigeration and air condition purpose. Such as air refrigeration, vapour compression, vapour absorption etc. In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012