Accelerating multi-echo T2 weighted MR imaging: analysis prior group-sparse optimization.

نویسندگان

  • Angshul Majumdar
  • Rabab K Ward
چکیده

This works addresses the problem of reconstructing multi-echo T2 weighted MR images from partially sampled K-space data. Previous studies in reconstructing MR images from partial samples of the K-space used Compressed Sensing (CS) techniques to exploit the spatial correlation of the images (leading to sparsity in transform domain). Such techniques can be employed to reconstruct the individual T2 weighted images. However, in the current context, the different images are not independent; they are images of the same cross section, and hence are highly correlated. In this work, we not only exploit the spatial correlation within the image, but also the correlation between the images to achieve even better reconstruction results. For individual MR images, CS based techniques lead to a sparsity promoting optimization problem in a transform domain. In this paper, we show how to extend the same framework in order to incorporate correlation between images leading to group sparsity promoting optimization. Group sparsity promoting optimization is popularly formulated as a synthesis prior problem. The synthesis prior formulation for group sparsity leads to superior reconstruction results compared to ordinary sparse reconstruction. However, in this paper we show that when group sparsity is framed as an analysis prior problem the reconstruction results are even better for proper choice of the sparsifying transform. An interesting observation of this work is that when the same sampling pattern is used to sample the K-space for all the T2 weighted echoes, group sparsity does not yield any noticeable improvement, but when different sampling patterns are used for different echoes, our proposed group sparsity promoting formulation yields significant improvement (in terms of Normalized Mean Squared Error) over previous CS based techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rank Awareness in Group-Sparse Recovery of Multi-Echo MR Images

This work addresses the problem of recovering multi-echo T1 or T2 weighted images from their partial K-space scans. Recent studies have shown that the best results are obtained when all the multi-echo images are reconstructed by simultaneously exploiting their intra-image spatial redundancy and inter-echo correlation. The aforesaid studies either stack the vectorised images (formed by row or co...

متن کامل

Optimal Pulse Sequence for Ferumoxides-Enhanced MR Imaging Used in the Detection of Hepatocellular Carcinoma: A Comparative Study Using Seven Pulse Sequences

OBJECTIVE To identify the optimal pulse sequence for ferumoxides-enhanced magnetic resonance (MR) imaging in the detection of hepatocelluar carcinomas (HCCs). MATERIALS AND METHODS Sixteen patients with 25 HCCs underwent MR imaging following intravenous infusion of ferumoxides. All MR studies were performed on a 1.5-T MR system, using a phased-array coil. Ferumoxides (Feridex IV) at a dose of...

متن کامل

Assessment of hemorrhage in pituitary macroadenoma by T2*-weighted gradient-echo MR imaging.

BACKGROUND AND PURPOSE Intratumoral hemorrhage occurs frequently in pituitary macroadenoma and manifests as pituitary apoplexy and recent or old silent hemorrhage. T2*-weighted gradient-echo (GE) MR imaging is the most sensitive sequence for the detection of acute and old intracranial hemorrhage. T2*-weighted GE MR imaging was used to investigate intratumoral hemorrhage in pituitary macroadenom...

متن کامل

Detection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.

OBJECTIVE The purpose of this study was to compare breath-hold three-dimensional (3D) rapid gradient-echo (GRE) MR imaging obtained before and after gadolinium chelate injection with T2-weighted fast spin-echo and T2-weighted breath-hold fast spin-echo (BHFSE) MR imaging in the detection of focal hepatic masses. SUBJECTS AND METHODS Fifty-three patients with 108 focal hepatic masses had, pros...

متن کامل

Head and neck paragangliomas: improved tumor detection using contrast-enhanced 3D time-of-flight MR angiography as compared with fat-suppressed MR imaging techniques.

BACKGROUND AND PURPOSE MR imaging techniques have proved their efficacy in imaging the head and neck region. In this study, we compared T1-weighted, dual T2-weighted, and fat-suppressed MR imaging and unenhanced and contrast-enhanced 3D time-of-flight MR angiography sequences for detection of head and neck paragangliomas. METHODS Thirty-one patients with 70 paragangliomas were examined. Four ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 210 1  شماره 

صفحات  -

تاریخ انتشار 2011