How Often Should We Monitor for Reliable Detection of Atrial Fibrillation Recurrence? Efficiency Considerations and Implications for Study Design

نویسندگان

  • Efstratios I. Charitos
  • Paul D. Ziegler
  • Ulrich Stierle
  • Derek R. Robinson
  • Bernhard Graf
  • Hans-Hinrich Sievers
  • Thorsten Hanke
چکیده

OBJECTIVE Although atrial fibrillation (AF) recurrence is unpredictable in terms of onset and duration, current intermittent rhythm monitoring (IRM) diagnostic modalities are short-termed and discontinuous. The aim of the present study was to investigate the necessary IRM frequency required to reliably detect recurrence of various AF recurrence patterns. METHODS The rhythm histories of 647 patients (mean AF burden: 12 ± 22% of monitored time; 687 patient-years) with implantable continuous monitoring devices were reconstructed and analyzed. With the use of computationally intensive simulation, we evaluated the necessary IRM frequency to reliably detect AF recurrence of various AF phenotypes using IRM of various durations. RESULTS The IRM frequency required for reliable AF detection depends on the amount and temporal aggregation of the AF recurrence (p<0.0001) as well as the duration of the IRM (p<0.001). Reliable detection (>95% sensitivity) of AF recurrence required higher IRM frequencies (>12 24-hour; >6 7-day; >4 14-day; >3 30-day IRM per year; p<0.0001) than currently recommended. Lower IRM frequencies will under-detect AF recurrence and introduce significant bias in the evaluation of therapeutic interventions. More frequent but of shorter duration, IRMs (24-hour) are significantly more time effective (sensitivity per monitored time) than a fewer number of longer IRM durations (p<0.0001). CONCLUSIONS Reliable AF recurrence detection requires higher IRM frequencies than currently recommended. Current IRM frequency recommendations will fail to diagnose a significant proportion of patients. Shorter duration but more frequent IRM strategies are significantly more efficient than longer IRM durations. CLINICAL TRIAL REGISTRATION URL Unique identifier: NCT00806689.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

سنجش استعداد ابتلا به فیبریلاسیون دهلیزی با استفاده از تحلیل‌های غیر خطی سیگنال الکتروکاردیوگرام

Atrial Fibrillation is a supra ventricular tachyarrhythmia, which is characterized by the deterioration of atrial mechanical function and aberrant. It has become a social and economic problem because a large percentage of the world population suffering from this disease. The early diagnosis of this fatal cardiac Arrhythmia can be prevented and managed it. In this study, we used non-invasive met...

متن کامل

Detecting and monitoring arrhythmia recurrence following catheter ablation of atrial fibrillation

Atrial fibrillation (AF) is the most common arrhythmia prompting clinical presentation, is associated with significant morbidity and mortality. The incidence and prevalence of this arrhythmia is expected to grow significantly in the coming decades. Of the available pharmacologic and non-pharmacologic treatment options, the fastest growing and most intensely studied is catheter-based ablation th...

متن کامل

Long-term Arrhythmia Monitoring in Cryptogenic Stroke: Who, How, and for How Long?

Cryptogenic stroke and transient ischemic attack (TIA) account for approximately one-third of stroke patients [1]. Paroxys-mal atrial fibrillation (PAF) has been suggested as a major etiology of these cryptogenic strokes [2, 3]. PAF can be difficult to diagnose because it is intermittent, often brief, and asymptomatic. PAF might be more prevalent than persistent atrial fibrillation in stroke an...

متن کامل

Arrhythmia/Electrophysiology A Comprehensive Evaluation of Rhythm Monitoring Strategies for the Detection of Atrial Fibrillation Recurrence Insights From 647 Continuously Monitored Patients and Implications for Monitoring After Therapeutic Interventions

Background—Intermittent rhythm monitoring (IRM) to detect atrial fibrillation (AF) recurrence is employed to evaluate the success of therapeutic interventions. In a large population of patients with continuous monitoring (CM), we investigated the sensitivity of various frequencies and durations of IRM strategies on the detection of AF recurrence, the dynamics behind AF recurrence detection, and...

متن کامل

Increased IL-17A in Atrial Fibrillation Correlates with Neutrophil to Lymphocyte Ratio

Background: Atrial Fibrillation (AF) is the most common cardiac arrhythmia and an independent risk factor for stroke among the elderly. A role for inflammation in the atrial remodeling as well as development and recurrence of AF is known. Objective: To compare IL-17A between patients with different types of AF and healthy individuals. Methods: IL-17A was measured in sera of 112 patients and 107...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014