Development of a Novel Stereoacuity Test Device Using a High-Resolution 3D Monitor

نویسندگان

  • Yo Iwata
  • Tomoya Handa
  • Hitoshi Ishikawa
چکیده

Purpose: To develop stereoacuity test using a high-resolution 3D monitor and examined the effects of the monitor on the measured stereoacuity. Methods: We conducted stereoacuity test using a high-resolution 3D monitor. This 3D monitor can show parallax of 27 s (crossed) at the minimum at measurement distance 40 cm, and circularly polarized glasses were used for binocular separation. Titmus stereo test (TST) and TNO stereotest (TNO) were performed for comparison. Results: The high-resolution 3D monitor, TST, and TNO average stereoacuity values were 35.0 ± 18.4, 50.0 ± 10.4, and 91.3 ± 53.0s, respectively. The stereoacuity value of the 3D monitor was significantly lower than that of the TST and TNO tests (p < 0.02, p < 0.0002, respectively). The stereoacuity value of the TST test was significantly lower than that of the TNO test (p = 0.002). Conclusion: We consider stereoacuity test using 3D monitor which can show various images is effective.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Stereoacuity Test Using a 3-Dimensional Display System in Children

The previously developed 3-dimensional (3D) display stereoacuity tests were validated only at distance. We developed a new stereoacuity test using a 3D display that works both at near and distance and evaluated its validity in children with and without strabismus. Sixty children (age range, 6 to 18 years) with variable ranges of stereoacuity were included. Side-by-side randot images of 4 differ...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Design and Manipulation 3D Imaging System by using Photodiode Grid

Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...

متن کامل

Evaluating stereoacuity with 3D shutter glasses technology

BACKGROUND To determine the stereoacuity threshold with a 3D laptop equipped with 3D shutter glasses, and to evaluate the effect of different shape and size of test symbols and different type of disparities to stereoacuity. METHODS Thirty subjects with a visual acuity in each eye of at least 0 logMAR and a stereoacuity of at least 32 arcsec (as assessed in Fly Stereo Acuity Test) were recruit...

متن کامل

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017