Detection of methamphetamine in sweat by EIA and GC-MS.

نویسندگان

  • J Fay
  • R Fogerson
  • D Schoendorfer
  • R S Niedbala
  • V Spiehler
چکیده

Sweat was collected with the PharmChekTM sweat patch and drugs were eluted from the collection pad of the patch. A solid phase, enzyme immunoassay using microtiter plates was modified for analysis of methamphetamine in sweat. After methamphetamine administration, sweat contains primarily parent methamphetamine. The immunoassay was determined to have crossreactivity relative to 100% for the methamphetamine (MA) calibrators; to 144% for methylenedioxymethamphetamine (MDMA); to 30% for d-amphetamine; to 21% for methylenedioxyamphetamine (MDA); and to 8% for I-methamphetamine. The optimum cutoff concentration for this modified assay was determined by receiver operating characteristic analysis to be 10 ng/mL amphetamine equivalents. At this cutoff concentration the assay had a diagnostic sensitivity of 84.5% and a diagnostic specificity of 93.2% versus gas chromatography-mass spectrometry (GC-MS). The positive predictive value at a prevalence of 50% was 86%. The intra-assay precision at 10 ng/mL was 9.9% (coefficient of variation, CV) and the interassay CV was 13%. Analysis of spiked patches at plus or minus 25 and 50% around the cutoff gave a percent positive threshold of approximately 50% at a cutoff of 10 ng/mL and a 95% confidence level for a positive result by the EIA between 15 and 20 ng/mL. Of 18 potential adulterants that might be injected into or under the patch, two (tile cleaner and cough syrup) caused a false-positive response by immunoassay. All results were confirmed by GC-MS. The clinical sensitivity and specificity of the overall analysis system (sweat collection and analysis) were 85 and 100%, respectively, using known methamphetamine dosing of volunteers (10, 20, and 25 mg) as the reference standard.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Qualitative detection of opiates in sweat by EIA and GC-MS.

Sweat was collected with the PharmChek sweat patch, and drugs were eluted from the collection pad of the patch. A solid-phase enzyme immunoassay (EIA) using microtiter plates was modified for the analysis of opiates in sweat. After opiate administration, sweat contains primarily parent opiate (heroin, codeine) and lipophilic metabolites (6-monoacetylmorphine [6-MAM]). The immunoassay was determ...

متن کامل

Detection of marijuana use by oral fluid and urine analysis following single-dose administration of smoked and oral marijuana.

We compared oral fluid testing to urine testing in subjects who were administered single doses of marijuana by smoked and oral routes. Oral fluid specimens were collected with the Intercept DOA Oral Specimen Collection Device, screened for THC with the Cannabinoids Intercept MICRO-PLATE Enzyme Immunoassay (EIA) utilizing a 1.0-ng/mL cutoff concentration, and confirmed for THC by gas chromatogra...

متن کامل

Excretion of methamphetamine and amphetamine in human sweat following controlled oral methamphetamine administration.

BACKGROUND Understanding methamphetamine (MAMP) and amphetamine (AMP) excretion in sweat is important for interpreting sweat and hair testing results in judicial, workplace, and drug treatment settings. METHODS Participants (n = 8) received 4 10-mg (low) oral doses of sustained-release S-(+)-MAMP HCl (d-MAMP HCl) within 1 week in a double-blind, institutional review board-approved study. Five...

متن کامل

Monitoring opiate use in substance abuse treatment patients with sweat and urine drug testing.

Although urine testing remains the standard for drug use monitoring, sweat testing for drugs of abuse is increasing, especially in criminal justice programs. One reason for this increase is sweat testing may widen the detection window compared to urine testing. Drug metabolites are rapidly excreted in urine limiting the window of detection of a single use to a few days. In contrast, sweat colle...

متن کامل

Validation of the Cozart Amphetamine Microplate EIA for the analysis of amphetamines in oral fluid.

The purpose of this study was to determine the performance characteristics of the Cozart Amphetamine Microplate EIA for detecting amphetamine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan Collection System from 135 volunteer donors from drug treatment clinics. A further 35 oral fluid samples were collected from volunteer donors who were not drug users. The samples w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 20 6  شماره 

صفحات  -

تاریخ انتشار 1996