Microbial air monitoring as a useful tool when commissioning bone marrow transplant units.
نویسندگان
چکیده
To the Editor—Bone marrow transplant patients are highly susceptible to airborne infections, which are mainly due to opportunistic microorganisms." Guidelines for the proper design of hospital rooms and heating, ventilation, and airconditioning (HVAC) systems have been published. Their aim is to control the concentration of airborne particles and their deposition onto surfaces, minimizing their introduction, production, and retention inside the rooms, thus protecting patients from environmental infections. We report our experience of microbial air monitoring carried out at a newly opened bone marrow transplant unit (BMTU), just before patient admission began. The study was carried out at the University Hospital in Parma, Italy. The BMTU consisted of 3 rooms and was equipped with an HVAC system, which had been certified by the installer as compliant with the required standards. Air sampling was performed in the 3 patient rooms (ambient air and air coming out of the HVAC diffusers); ambient air in the corridor was also sampled. Air samples were collected using both active and passive sampling methods. Active samples were collected using a DUOSAS 360 (Pbi), with a flow rate of 180 L/min and a suction volume of 1,000 L. To sample the air coming out of the HVAC system, the sampler was placed at a distance of about 30 cm from the air outlet. Results were expressed as colony-forming units (CFU) per cubic meter. Petri dishes with a diameter of 9 cm were used for passive sampling to determine the index of microbial air contamination (IMA). The IMA was expressed as CFU per square meter per hour. Tryptic soy agar was used for bacteria isolation, with incubation at 36°C ± 1°C for 48 hours, while Sabouraud dextrose agar with chloramphenicol was used for fungi isolation, with incubation at 22°C ± 1°C for 120 hours. Microbial air samples collected in patient rooms before the opening of the BMTU showed high bacterial and fungal contamination values, both in ambient air (mean ± standard deviation; bacterial: 12 ± 10.6 CFU/m, 0 ± 0 CFU/m/h; fungal: 120 ± 33.6 CFU/m, 33 ± 58 CFU/m/h) and in the air supplied by the HVAC system (bacterial: 6.67 ± 3.05 CFU/m; fungal: 32 ± 34.65 CFU/m). Fungi were isolated in 100% of active samples and 75% of passive samples collected from ambient air and in 77% of air samples collected from the HVAC system. Four more samplings were performed, each one preceded by an accurate cleaning and disinfection, but there was no improvement in air quality. Bacterial and fungal air contamination values for the first 5 samplings are shown in Table 1. A closer inspection of the HVAC system was carried out, revealing an incorrect setup of the ventilation system's parameters (pressure and number of air changes). After the problem was corrected, bacterial counts decreased dramatically, both for ambient air and for air outlets. No fungal contamination was detected (Table 1, sixth sampling). This experience demonstrates that microbiological air control may prove to be a useful tool in identifying hazardous situations and assessing the efficacy of corrective actions. We support what Eickhoff suggested in 1994, namely, that environmental sampling should be considered in ultra-highrisk units such as BMTUs and other settings in which patients temporarily have no functioning host defense mechanisms and any opportunistic microorganism that comes along may cause a fatal infection. The use of an active sampler capable of collecting large volumes of air in short periods of time is recommended to evaluate the concentration of viable particles and to detect small numbers of fungal spores in highly filtered areas. Settle plates, which are available in every hospital, can be used to specifically measure how air biocontamination contributes to the biocontamination of critical surfaces. Plates can also be used to generally measure microbial air quality and to highlight critical situations. Settle plates are less sensitive than active sampling methods in collecting fungi and buoyant respirable particles, since they rely on gravity and tend to select for larger particles. However, in our study they helped reveal an anomalous situation. Long sampling periods may increase their sensitivity, as indicated in the European Union guidelines to good manufacturing practice. In this document, threshold values for active (CFU/m) and passive (settle plates 9 cm in diameter exposed for 4 hours) samplings are listed. Doubts remain about the potential usefulness of particulate sampling in detecting contamination problems. The Centers for Disease Control and Prevention 2003 guidelines include particulate sampling among the areas of future research, particularly to determine whether it could replace microbiological sampling for measuring the air quality of clean environments (operating rooms, hematopoietic stem cell transplantation units, etc.). However, particle counters are not available in every hospital. Furthermore, a study by Landrin et al showed that no correlation exists between microbial counts and particle counts in empty ventilated operating rooms equipped with high-efficiency particulate air (HEPA) filters. In fact, in many cases high particle counts were not associated with an increase in air microbiological counts, indicating that such particles were not ascribable to microbial contamination. As a final thought, whatever approach is adopted, all environmental control activities should be purposeful and well
منابع مشابه
Microbial Evaluation of Neutropenic Diet in Bone Marrow Transplant Department in Iran
Background: The use of a neutropenic diet after hematopoietic stem cell transplantation (HSCT) was instituted more than 30 years ago. This diet was targeted toward preventing from infection with organisms colonizing the gastrointestinal tract and the food-borne pathogens, which are the most important cause of illness and death in developing countries. Regarding this, the present study aimed to ...
متن کاملThe Results of Bone Marrow Transplantations. in 10 Iranian Patients Travelled and Treated Abroad are Presented Here
SUMMARY Up to 15 years ago, bone marrow transplantation was experimental, but in the recent years it has gained an important role in the field of Medicine, and it has clearly been established as a therapeutic modality for a wide range of diseases. During 1950-1955 when marrow transplant was first attempted in human, little was known about transplant antigens. Supportive care techniques such...
متن کاملConcurrence of Nosocomial Infections with Microorganisms Spreading in the Air of Hospital Wards
Abstract Background and objectives: A Nosocomial infection is one of the Leading problems causing high mortality among hospitalized patients. This study aimed at confirming the concurrence of Nosocomial infections with microorganisms spreading in the air of hospital wards. Material and Methods: This study was conducted in 2009 at ValieAsr Hospital in Tehran, Iran. The Samples were taken from th...
متن کاملBone Marrow Transplant (BMT) is the Main Cureavailable for Thalassamia
Introduction: The thalassamias refer to a diverse group of hemoglobin disorders characterized by a reduced synthesis of one or more of globin chains (α,β, γ, δβ,γδβ, δ and εγδβ).The main cure available today for thalassamia is bone marrow transplantation (BMT) from compatible donor.On December 3, 1981 a 14-month-old child with β-thalassemia major recieved BMT from his HLA-identical sister in...
متن کاملDifference in the Cytomegalovirus-related clinical laboratory findings between patients with bone marrow and kidney transplantation
Background: Despite close monitoring of transplant patients, cytomegalovirus (CMV) infection remains one of the most critical problems in the field of transplantation. This study aims to investigate the relationship between CMV viral load and clinical laboratory findings in transplant recipients. Materials And Methods: Thirty-four transplant recipients comprising 15 kidney transplant (KT) reci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Infection control and hospital epidemiology
دوره 33 1 شماره
صفحات -
تاریخ انتشار 2012