CSF Pulsation Artifacts on ADC Maps Obtained with Readout-segmented EPI
نویسندگان
چکیده
PURPOSE Diffusion-weighted imaging (DWI) using readout-segmented EPI (rs-EPI) can minimize distortion and blurring artifacts; however, we sometimes encounter cerebrospinal fluid (CSF) pulsation artifacts on apparent diffusion coefficient (ADC) maps, especially when the number of readout segments (NRS) is increased. The purpose of this study was to evaluate the effect of the NRS on the CSF pulsation artifacts in the ADC maps of healthy volunteers. METHODS In 10 healthy volunteers, we obtained DWI from rs-EPI with a b-value of 0 and 1000 s/mm2. The NRS was set to 5, 7, or 9. An ADC map was generated from the trace image and the b = 0 image. Each scan was performed twice. A circular region of interest (ROI) was drawn in the pons and bilateral thalami. The standard deviation (SD) of the ROI was measured to assess the artifacts. Bilateral SD values were averaged for the ROIs in the thalami. The SD values from two successive scans of each NRS were averaged for the pons and thalami, respectively. For the qualitative analysis, the CSF pulsation artifacts on each ADC map were graded by two observers independently as 0, no artifact; 1, mild artifact; 2, moderate artifact; or 3, severe artifact. RESULTS In the quantitative analysis, the SD values tend to increase with the increasing of NRS in both thalami and pons; however, the difference in the SD values from each NRS did not reach a statistically significant level. In the qualitative analysis, there was a statistically significant difference in the scores between 5 and 9 segments and between 7 and 9 segments with both the observers, respectively (P < 0.05). CONCLUSION The CSF pulsation artifacts on ADC maps obtained with rs-EPI are affected by the NRS.
منابع مشابه
Single-Shot and Segmented EPI Ghost Artifacts Removal with Two-Dimensional Phase Correction
Introduction Asymmetry between odd and even echoes generates Nyquist ghost artifact in a single-shot EPI , and further enhances multiple ghost artifacts in a segmented EPI. These ghost artifacts not only severely degrade EPI image quality, but may lead to incorrect ADC values in EPI based diffusion measurements (1). Methods currently available for odd-even-echo asymmetry compensation include on...
متن کاملTwice Refocused Inner Volume EPI DTI of the Spinal Cord: Initial Findings
Introduction Diffusion tensor imaging of the spinal cord is challenging due to the required high resolution, the susceptibility differences of the involved tissues and the pulsation of the surrounding CSF. Single shot Echo-Planar Imaging (EPI) is the method of choice, but has the drawback of being sensitive to local gradients when long readout trains are used. The readout train can be shorten b...
متن کاملDWI of the spinal cord with reduced FOV single-shot EPI.
Single-shot echo-planar imaging (ss-EPI) has not been used widely for diffusion-weighted imaging (DWI) of the spinal cord, because of the magnetic field inhomogeneities around the spine, the small cross-sectional size of the spinal cord, and the increased motion in that area due to breathing, swallowing, and cerebrospinal fluid (CSF) pulsation. These result in artifacts with the usually long re...
متن کاملMulti-Shot, Diffusion-Weighted Imaging at 3T using Readout-Segmented EPI and GRAPPA
D. A. Porter, R. M. Heidemann MR Applications Development, Siemens Medical Solutions, Erlangen, Germany Introduction Diffusion-weighted, single-shot EPI suffers from considerable susceptibility-based distortion artefact at 3T. Although the effects can be mitigated by using a partially parallel imaging (PPA) technique to reduce the effective echo-spacing [1], there are significant residual artef...
متن کاملDiagnostic Performance of Diffusion Tensor Imaging with Readout-segmented Echo-planar Imaging for Invasive Breast Cancer: Correlation of ADC and FA with Pathological Prognostic Markers
PURPOSE To assess the diagnostic performance of readout-segmented echo-planar diffusion tensor imaging (DTI based on rs-EPI) for breast cancer and to determine the correlation between the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values obtained from DTI based on rs-EPI with prognostic markers of invasive breast cancer. MATERIALS AND METHODS This retrospective study ...