Detection of melamine in milk powder and human urine.

نویسندگان

  • Tsung-Hsuan Tsai
  • Soundappan Thiagarajan
  • Shen-Ming Chen
چکیده

Detection of melamine has been developed by employing oxidized polycrystalline gold electrode (poly GE). The poly GE was directly utilized for the detection of melamine using differential pulse voltammetry (DPV) and impedimetry. Poly GE successfully showed the oxidation peak for melamine adsorption at 1.1 V is purely based on the detection of adsorption signals of melamine at the electrode surface. Furthermore, the melamine adsorbed poly GE surface has been studied using atomic force microscopy (AFM). Poly GE successfully detects the oxidation signals of melamine in the linear range of 0.05-1.31 ppm in laboratory samples. The proposed poly GE successfully detects the melamine signal (0.06-0.85 ppm) in tainted milk powder samples. It also exhibits two well-separated anodic oxidation peaks for urine and melamine in melamine-spiked human urine samples. Gas chromatography-mass spectrometry (GC-MS) was also employed for the successful detection of melamine in the above proposed real samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Follow-up results of children with melamine induced urolithiasis: a prospective observational cohort study.

BACKGROUND Melamine-contaminated milk powder was the cause of the 2008 outbreak of urolithiasis in young children and infants in China, but the prognosis of these children remains unknown. We hypothesized that urolithiasis induced by melamine-contaminated milk powder may be associated with secondary renal injury. METHODS A total of 8335 children (≤6 years old) with a history of consuming mela...

متن کامل

Melamine-contaminated milk formula and its impact on children.

The melamine contaminated milk powder contamination scandal occurred in China in 2008. Its main consequences so far have been urinary stone formation in children with associated renal damage and increased child mortality. Eight years have passed, but food safety issues still remain of concern in the daily lives of millions of Chinese. Vigilance is required to ensure no recurrence of such food s...

متن کامل

Penetration Depth Measurement of Near-Infrared Hyperspectral Imaging Light for Milk Powder

The increasingly common application of the near-infrared (NIR) hyperspectral imaging technique to the analysis of food powders has led to the need for optical characterization of samples. This study was aimed at exploring the feasibility of quantifying penetration depth of NIR hyperspectral imaging light for milk powder. Hyperspectral NIR reflectance images were collected for eight different mi...

متن کامل

Rapid Testing for Adulteration of Yogurt Candy using Near-infrared Spectroscopy and Adulterant Screen

Melamine is an adulterant commonly found in milk, as it can increase the nitrogen content. Therefore, its apparent protein content, resulting in a better market price. Melamine adulteration can be fatal, as was highlighted in 2008 when six infants died due to melamine adulteration in milk powder and thousands were sickened in China. Consequently, there have been stricter regulations globally an...

متن کامل

High-throughput trace melamine analysis in complex mixtures.

Ambient ionization using a low-temperature plasma (LTP) probe combined with tandem mass spectrometry (MS/MS) allows detection and quantitation of melamine in milk powder, whole milk and other products at levels down to low ppb in analysis times of a few tens of seconds.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of agricultural and food chemistry

دوره 58 8  شماره 

صفحات  -

تاریخ انتشار 2010