Calibration of High-Precision Flexure Parallel Robots

نویسنده

  • Albert Einstein
چکیده

i Calibration of High-Precision Flexure Parallel Robots Over the last decades, calibration techniques have been widely used in robotics since they represent a cost-effective solution for improving the accuracy of robots and machine-tools. They only involve software modification without the necessity of revising the robot design or tightening the manufacturing tolerances. The goal of this thesis is to propose a procedure that guides the engineer through the calibration of a given multi-DOF flexure parallel robot within sub-μm accuracy. Two robots having 3 and 6 degrees of freedom have been considered as a case-study throughout the work. As in any calibration procedure, the work has been conducted on three different fronts: measurement, data processing and validation. The originality of this thesis in respect to published material lies in these three points. Measurements were carried out in a chamber inside which the measuring environment was protected against mechanical and thermal perturbations. In particular, the temperature variations experienced by the different parts of the measuring loop during a typical measurement session were stabilized within less than ± 0.1 oC. Proposed procedures allow the collection of reliable sets of data on the two robots. Delicate aspects of practical implementation are discussed. In particular, the problem of collecting a complete set of 6D data within accuracies in the nanometre range, for which there is still a lack of standard equipment, is solved using a procedure comprising several steps and making use of existing instrumentation. Suggestions for future investigations are given, regarding either long-term research problems or short-term industrial implementation issues. Data processing was performed using two different techniques in order to reach absolute accuracies after calibration better than ± 100 nm for translations and ± 3 arcsec for rotations (± 0.3 arcsec inside a more restricted range of ± 0.11o). The first method is called the “model-based approach” and requires the use of a known analytical relationship between the motor and operational coordinates of the robot. This relationship involves a certain number of parameters that can be related to the geometry of the robot (physical models) or simply mathematical coefficients of an approximating mathematical function (behavioural models). In the case of high-precision multi-DOF flexure parallel robots, we show that polynomial-based behavioural models are preferable to physical models in terms of accuracy for data processing tasks. In the second method, called the “model-free approach”, the user does not need to model explicitly the main error sources (or their effect) affecting the robot accuracy. A model-free approach has been implemented using Artificial Neural Networks. We show that, using a heuristic search based on a decision-tree, the architecture of a network with satisfactory prediction capability can be found systematically. In particular, this algorithm can find a network able to predict the direct correspondence between the motor and operational coordinates (within the desired accuracy) without the help of the Inverse Geometric Model of the robot, i.e. even if the nominal geometry of the robot being calibrated remains unknown. This result contradicts conclusions reported by previous researchers. It is claimed that any robot (not necessarily a high-precision flexure parallel mechanism) can be calibrated by means of a “neural approach” in which the architecture of an appropriate network is determined with the help of our algorithm. Two examples (other than the robots measured in this thesis) are given to illustrate this universality. In the last part of this work, we provide a feasibility study on the use of indentation, a technique traditionally used for material testing, as a validation procedure to assess the accuracy of the calibrated degrees of freedom. The industrial interest of this technique lies in the fact that the robot is asked to execute similar motions to those involved in a real micro-machining operation. Key-words: robot calibration, sub-μm accuracy, flexure parallel robots, neural networks, indentation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new concept of modular kinematics to design ultra-high precision flexure-based robots

This work deals with the kinematic conception and the mechanical design of ultra-high precision robots, which are at present costly to develop, both in time and money. The aim of this paper is thus to introduce a new modular concept of kinematics which allows to significantly reduce the time-to-market and a new double-stage flexure-based pivot. Regarding the modular concept of kinematics, this ...

متن کامل

Experimental calibration of an active space telescope with flexure joints

In order to reach a micrometer accuracy, a suitable model of a space telescope needs to be developed and validated through calibration. Since high velocity is not required in such an application, the dynamic effects can be neglected and only geometric and/or static calibration has to be considered. Moreover, measurements for calibration are performed in a clean room under controlled pressure, t...

متن کامل

Concept of modular flexure-based mechanisms for ultra-high precision robot design

This paper introduces a new concept of modular flexure-based mechanisms to design industrial ultra-high precision robots, which aims at significantly reducing both the complexity of their design and their development time. This modular concept can be considered as a robotic Lego, where a finite number of building bricks is used to quickly build a high-precision robot. The core of the concept is...

متن کامل

Design and analysis of a novel 6-DOF redundant actuated parallel robot with compliant hinges for high precision positioning

This paper presents the design and modeling of a new 6-DOF 8-PSS/SPS compliant dual redundant parallel robot with wide-range flexure hinges. This robot can achieve either high accurate positioning or rough positioning as well as a 6-DOF active vibration isolation and excitation to the payload placed on the moving platform. Adopting a kind of wide-range flexure hinge, we establish the kinematics...

متن کامل

Using New Techniques and Devices within the Set of Tiba Body Roller Hamming Robots

In this article, new techniques and technologies have been tried and tested in the installation and commissioning of Roller Home industrial robots, in order to produce a Tiba car with a focus on cost reduction. Due to the fact that press equipment for automobile parts requires a lot of expenses, it was decided to use robots with the same function of roller to reduce costs and increase the q...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006