Determination of acoustic noise characteristics and development of silent EPI for auditory fMRI
نویسندگان
چکیده
S. Schmitter, M. Amann, L. Schad Deutsches Krebsforschungszentrum, Heidelberg, Germany Introduction: MR scanner noise is often a problem in fMRI studies, especially in auditory experiments. The BOLD signal induced by the scanner noise may interfere with the auditory fMRI signal [1]. Additionally the scanner's sound pressure level (SPL) of up to 110 dBA causes discomfort or anxiety in many patients [2]. In this work, a silent EPI sequence using a pure sinusoidal readout gradient is presented with a noise reduction of about 11 dBA compared to a conventional EPI sequence with the same imaging parameters. The new sequence was tested in an fMRI experiment with auditory stimulation. In this block-design experiment, a reliable BOLD response of up to 6% signal change was detected in the primary auditory cortex.
منابع مشابه
Silent high resolution echo-planar imaging for auditory fMRI
Introduction Acoustic scanner noise during image acquisition is a well-known problem in functional MRI (fMRI). The noise is created by gradient coil switching and causes an unwanted BOLD signal in the auditory cortex [1]. Most of the time, echo-planar imaging (EPI) is used for fMRI. However, this sequence produces high acoustic noise due to fast switching of trapezoidal gradients. The sound pre...
متن کاملMethodological challenges and solutions in auditory functional magnetic resonance imaging
Functional magnetic resonance imaging (fMRI) studies involve substantial acoustic noise. This review covers the difficulties posed by such noise for auditory neuroscience, as well as a number of possible solutions that have emerged. Acoustic noise can affect the processing of auditory stimuli by making them inaudible or unintelligible, and can result in reduced sensitivity to auditory activatio...
متن کاملSilent sparse sampling for auditory fMRI
Introduction: The investigation of complex auditory processes has been difficult using fMRI due to the excessive image acquisition noise, typically 100-130 dB. The development of the sparse sampling paradigm was a major improvement in auditory research [1]. In this method, only a single volume is acquired with a long TR usually 12-16 seconds. The timing of the stimulus is jittered relative to t...
متن کاملInterleaved silent steady state (ISSS) imaging: a new sparse imaging method applied to auditory fMRI.
The acoustic scanner noise that is generated by rapid gradient switching in echo planar imaging (EPI) is an important confounding factor in auditory fMRI. "Sparse imaging" designs overcome the influence of scanner noise on stimulus presentation by acquiring single brain volumes following a silent stimulus presentation period. However, conventional sparse imaging requires assumptions about the t...
متن کاملFunctional fields in human auditory cortex revealed by time-resolved fMRI without interference of EPI noise.
The gradient switching during fast echoplanar functional magnetic resonance imaging (EPI-fMRI) produces loud noises that may interact with the functional activation of the central auditory system induced by experimental acoustic stimuli. This interaction is unpredictable and is likely to confound the interpretation of functional maps of the auditory cortex. In the present study we used an exper...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005