Refractive accuracy with light-adjustable intraocular lenses.

نویسندگان

  • Eloy A Villegas
  • Encarna Alcon
  • Elena Rubio
  • José M Marín
  • Pablo Artal
چکیده

PURPOSE To evaluate efficacy, predictability, and stability of refractive treatments using light-adjustable intraocular lenses (IOLs). SETTING University Hospital Virgen de la Arrixaca, Murcia, Spain. DESIGN Prospective nonrandomized clinical trial. METHODS Eyes with a light-adjustable IOL (LAL) were treated with spatial intensity profiles to correct refractive errors. The effective changes in refraction in the light-adjustable IOL after every treatment were estimated by subtracting those in the whole eye and the cornea, which were measured with a Hartmann-Shack sensor and a corneal topographer, respectively. The refractive changes in the whole eye and light-adjustable IOL, manifest refraction, and visual acuity were obtained after every light treatment and at the 3-, 6-, and 12-month follow-ups. RESULTS The study enrolled 53 eyes (49 patients). Each tested light spatial pattern (5 spherical; 3 astigmatic) produced a different refractive change (P<.01). The combination of 2 light adjustments induced a maximum change in spherical power of the light-adjustable IOL of between -1.98 diopters (D) and +2.30 D and in astigmatism of up to -2.68 D with axis errors below 9 degrees. Intersubject variability (standard deviation) ranged between 0.10 D and 0.40 D. The 2 required lock-in procedures induced a small myopic shift (range +0.01 to +0.57 D) that depended on previous adjustments. CONCLUSIONS Light-adjustable IOL implantation achieved accurate refractive outcomes (around emmetropia) with good uncorrected distance visual acuity, which remained stable over time. Further refinements in nomograms and in the treatment's protocol would improve the predictability of refractive and visual outcomes with these IOLs. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Light-adjustable lens.

PURPOSE First, to determine whether a silicone light-adjustable intraocular lens (IOL) can be fabricated and adjusted precisely with a light delivery device (LDD). Second, to determine the biocompatibility of an adjustable IOL and whether the lens can be adjusted precisely in vivo. METHODS After fabrication of a light-adjustable silicone formulation, IOLs were made and tested in vitro for cyt...

متن کامل

A Rapid and Convenient Procedure to Evaluate Optical Performance of Intraocular Lenses

A new portable lens scanner was developed and tested for measuring focal lengths and relative contrast transfer of monoand multifocal intraocular lenses (IOLs). A photograph of a natural scene was imaged in white light through an IOL in a water-filled cuvette, with their +21D base power largely neutralized by a −20D trial lens, using a USB monochrome video camera that could be focused via a lap...

متن کامل

Light-adjustable intraocular lens in post-LASIK and post-traumatic cataract patient.

The case illustrates the use of a light-adjustable intraocular lens (IOL) in a patient who had had refractive surgery and developed blunt trauma with resultant flap damage and traumatic cataract. Consistent with early reports of the light adjustable IOL, which show positive results in non-LASIK eyes, this case suggests that the light-adjustable IOL may have similar benefits in the post-LASIK ey...

متن کامل

Visual axial PSF of diffractive trifocal lenses.

The ophthalmic applications of a diffractive trifocal lens design with adjustable add powers and light distribution in the foci are investigated. Axial PSFs of the trifocal lenses are calculated and analyzed as a function of the design parameters and the eye pupil size. The optical performance in actual eyes is also simulated by including the measured ocular wave aberration functions of human e...

متن کامل

The adjustable refractive surgery concept (ARS)

The primary goal of refractive surgery is the smallest residual refractive error and preserved contrast sensitivity with the same visual capacity under bright and dim illumination. Corneal refractive surgery cannot correct very high ametopias; from -10 to -14 D is the limit of myopia correction in the cornea and from +4 to +6 D, the limit of hyperopia correction. Intraocular refractive surgery ...

متن کامل