Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

نویسندگان

  • M. R. Deevband
  • P. Abdolmaleki
  • M. R. Kardan
  • H. R. Khosravi
  • M. Taheri
  • F. Nazeri
  • N. Ahmadi
چکیده

*Corresponding author: Dr. Parviz Abdolmaleki, Department of Biophysics, Tarbiat Modares University, P. O. Box 14155-6446, Tehran, Iran. Fax: +98 21 82884717 E-mail: [email protected] Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutroninduced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical etching was used to enlarge track diameter which was made by low energy recoil protons. Before electrochemical etching, a chemical etching was performed for 1 hour. The responses were also calculated by Monte Carlo simulations, using MCNPX code in different energy bins considering H, C and O recoils. The total registered efficiency and partial contributions of the efficiency, due to interactions with each constituent of CR-39, were calculated. Results: The optimized condition of etchant was obtained to be 6N KOH 15kV.cm-1, and 6 hours etching time. The obtained results show that track efficiency of CR-39 was a function of incident neutron energy. The tracks caused by O and C recoil nuclei were negligible for neutron energies lower than 1 MeV. At neutron energies lower than 1 MeV, only recoil protons would have sufficient energy to leave visible tracks. But, O and C recoils had important contributions in overall response of PADC at neutron energies of few MeV. Conclusion: The efficiency of a CR-39 based dosemeter could be calculated by MCNPX code and the results were in a good agreement with experimental results in energy range of 241Am – Be bare source and 241Am-Be was softened with a spherical polyethylene moderator of radius of 20 cm. Iran. J. Radiat. Res., 2011; 9(2): 95­102

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...

متن کامل

The plastic tray effect on the spectrum of photoneutrons prudused by 18 MV medical linac using the Monte Carlo method

Introduction: One of the important problems of using high energy linacs is the production of photoneutrons. High energy medical linacs produce secondary neutrons. These phtoneutrons increase patient dose   Materials and Methods: In this study, the effect of plastic trays on spectrum of photoneutrons produced by 18MV linac is investigated using the MCNP4C code...

متن کامل

شبیه‌سازی تابع پاسخ سوسوزن‌های آلی به تابش گاما و نوترون با استفاده از کدهای مونت کارلوی FLUKA،MCNPX و SCINFUL

In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...

متن کامل

شبیه‌سازی مونت کارلو یک دستگاه پرتودهی نوترونی به منظور تعیین بازده آشکارسازهای نوترون‌های حرارتی

In this work, a neutron irradiating system containing six Am/Be neutron sources in a graphite moderator, which produces a relatively high and uniform thermal neutron flux in an irradiating cavity at the center of the system , has been  simulated .The thermal neutron flux in the center of the system has then been calculated and compared with experimental results  measured in a cavity a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011