Rapid-scan pump–probe spectroscopy with high time and wave-number resolution: optical-Kerr-effect measurements of neat liquids
نویسندگان
چکیده
A system for the rapid-scan (RS) acquisition of time-resolved nonlinear spectroscopic signals, capable of femtosecond resolution over a range of tens of picoseconds, is presented. Operationally, the system is based on a magnetically driven, commercially available velocity transducer that continuously scans a probe delay line relative to a fixed delay line while data are recorded on the fly and in real time. A simple calibration and data time-scale linearization are carried out and tested on optical-heterodyne-detected optical-Kerr-effect measurements. These results are compared with data acquired with a detection system that is based on a stepped delay-line lock-in amplifier. It is found that the RS system is favorable in several areas of signal acquisition, including signal-to-noise ratio, acquisition time, spectral resolution in the Fourier-transformed data, and immunity to artifacts such as baseline distortions.
منابع مشابه
Constructing and Commissioning HELIOS – A High Harmonic Generation Source for Pump-
Terschlüsen, J. A. 2016. Constructing and Commissioning HELIOS – A High Harmonic Generation Source for Pump-Probe Measurements with sub 50 fs Temporal Resolution. The Development of Experimental Equipment for Extreme Ultraviolet Spectroscopy. Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology 1360. 80 pp. Uppsala: Acta Universitatis Upsaliensis. ...
متن کاملSub-100 fs two-color pump-probe spectroscopy of Single Wall Carbon Nanotubes with a 100 MHz Er-fiber laser system
An extremely compact and versatile near-infrared two-color femtosecond pump-probe spectroscopy apparatus based on an amplified Erfiber laser system is presented and applied to the characterization of the relaxation dynamics of single-wall carbon nanotubes with fundamental absorption in the 2 μm spectral region. By implementing a fast-scan technique, dynamics as long as 3 ps are acquired in 5 s ...
متن کاملاندازهگیری ضریب شکست غیر خطی در شیشههای آلاییده به بلورهای نیمرسانا
There are several techniques in use for non-linear refractive index measurement, namely, interferometric techniques, in which conventional inter-ferometers are used, degenerate for wave mixing (DFWM), and z-scan, Each of these techniques suffers from some shortcmings. For example conventional interferometers like Fabry-Perot and Twyman-Green need high quality optical components, unwanted refl...
متن کاملOptical Pump-Terahertz Probe Spectroscopy of Condensed Phase Reaction Dynamics
The general theoretical and experimental principles of optical pump-THz probe spectroscopy of chemical reactions in liquids is presented. Background on specific difficulties encountered in the experimental observation is reviewed. Chiefly, signal-to-noise ratios currently limit the quality of information that can be extracted from optical pump-THz probe data on chemical reactions. This issue is...
متن کاملTitle of dissertation : THE OPTICAL KERR EFFECT OF LIQUIDS
Title of dissertation: THE OPTICAL KERR EFFECT OF LIQUIDS Xiang Zhu, Doctor of Philosophy, 2007 Dissertation directed by: Professor John T. Fourkas Department of Chemistry and Biochemistry Optical Kerr effect (OKE) spectroscopy has found broad use in monitoring ultrafast dynamics in transparent media. I demonstrated that by using two pump pulses with independently-controllable polarizations, in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1995