Correction Factors for the Calibration of Encapsulated Radium Sources

نویسندگان

  • R. M. Lee
  • T. P. Loftus
چکیده

Several aspects of the procedure and corrections for the calibration of encapsulated radium sources at NBS have recently been investigated. It was found that a chamber equipped with a guard-ring type electrode system allowing the use of a vibrating reed electrometer as a current detector provides more versatility and precision than the gold-leaf electroscope now in use for routine calibrations. Absorption corrections for the U.S. primary national radium standards have been determined for the NBS chamber: 0.78 percent for standard 5440 and 1.01 percent for standard 5437. The Owen-Naylor integral equation for absorption of rays in the walls of cylindrical radium sources has been evaluated by a power series expansion of the integrand. Absorption coefficients and correction factors for platinum and Monel metal (materials commonly used for source capsules) have been computed for the NBS chamber.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Calibrator Performance and Quality Control

Two different dose calibrators were studied and their performance measured using the following tests: (A) linearity of response over all activity ranges, (B) accuracy when measuring some commonly used radionuclides, (C) the effect of container configuration on the accuracy of measurement, and (D) daily and long-term stability of the instrument. For each instrument tested, a good linear response...

متن کامل

Diode calibration for dose determination in total body irradiation

Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...

متن کامل

بررسی مواد رادیواکتیو سنگین رادون و رادیوم در رودها و آب شرب منطقه رامسر به وسیله دستگاه PRASSI

 Inhalation of radon gas 222Rn, which is a decay product of 226Ra, and its decay products accounts for typically about half of the effective doses received by public from all natural sources of ionizing radiation. Radon alpha particles can initiate a series of molecular and cellular events that culminates in the development of lung and other cancers. Also, 226Ra in the environment is widely dis...

متن کامل

Photometer for Measuring the Scotopic Candlepowers of Self-luminous Ophthalmic Test Objects.

A PHOTOMETER is described with which the scotopic candlepowers of very feeble light sources (down to about 10(-9) candle) can be measured. Small spots of radium paint, 2 or 3 mm. in diameter and having candlepowers in the range covered, are now used (Livingston) to plot the dark-adapted visual field, and the present photometer was designed primarily for their calibration. The radium paint emits...

متن کامل

Producing 65Zn and 60Co gamma sources for energy and efficiency calibration of gamma spectrometry systems

Precise calibration of energy and efficiency of gamma spectrometry systems for different geometries is very important. In most cases, preparation of these sources for educational and research centers  is very difficult due to high costs and lack of access to the reactor. The purpose of this paper is to explain the procedure for production of calibration sources 65Zn and 60Co using instrumental ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006