[A rare case of two mechanisms of prosthetic valve dysfunction in the same patient].
نویسندگان
چکیده
Prosthetic valve dysfunction is a significant clinical event. Determining its etiological mechanism and severity can be difficult. The authors present the case of a 50-year-old man, with two mechanical valve prostheses in aortic and mitral positions, hospitalized for decompensated heart failure. He had a long history of rheumatic multivalvular disease and had undergone three heart surgeries. On admission, investigation led to a diagnosis of severe dysfunction of both mechanical prostheses with different etiologies and mechanisms: pannus formation in the prosthetic aortic valve and intermittent dysfunction of the mitral prosthesis due to interference of a ruptured chorda tendinea in closure of the disks. The patient was reoperated, leading to significant improvement in functional class.
منابع مشابه
Prosthetic valve endocarditis caused by multidrug-resistant Candida albicans in a patient with myelodysplasia syndrome: A case report and literature review
Background and Purpose: Candida endocarditis is an infrequent disease with a high mortality rate, which commonly occurs in immunosuppressed patients with cardiac valve replacement. We reported a 70-year-old woman diagnosed with Candida prosthetic valve endocarditis (PVE). This study also involved a review of all published cases of Candida PVE from 1970. Case report: Herein, we reported a 70-ye...
متن کاملSuccessful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...
متن کاملA rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure
Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...
متن کاملSpontaneous Spinal Epidural Hematoma in a Patient With a Prosthetic Valve
Spontaneous Spinal Epidural Hematoma (SSEH) is a rare spinal condition. Early surgical intervention is generally indicated to prevent serious permanent neurological deficits. We encountered a case of spontaneous spinal epidural hematomas associated with motor weakness that was treated successfully by surgical evacuation.
متن کاملTricuspid Valve Endocarditis in an Intravenous Drug Abuser: A Case Report
Recently, there have been more reports of cardiac valve infections due to the increasing number of intravenous (IV) drug abusers and chronic renal failure patients. Among cardiac valves, tricuspid valve is most commonly affected in the course of endocarditis. Appropriate management of these patients is a challenging and controversial issue in the field of cardiac surgery. Treatment options in s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology
دوره 32 12 شماره
صفحات -
تاریخ انتشار 2013