Evaluation of blood pressure measuring devices with special reference to ambulatory systems.
نویسندگان
چکیده
As ambulatory blood pressure measurement becomes more widely accepted in hypertension research and in the clinical management of high blood pressure, the number of devices available on the market has increased considerably, reflecting the clinical demand. These devices are expensive, both in terms of capital and running costs. As we rely increasingly on data produced by ambulatory systems, it becomes increasingly important that they be shown to be accurate. Initially protocols for the validation of ambulatory devices were designed on an ad hoc basis, so that many studies were inadequately designed and comparison of data between studies was usually impossible. The American National Standard published by the Association for the Advancement of Medical Instrumentation (AAMI) remedied this situation in part, and the recent publication of the British Hypertension Society (BHS) protocol for the validation of ambulatory systems has further advanced the demand for accuracy. The BHS protocol includes most of the AMMI standard recommendations, but in addition there are sections on observer training, in-use assessment and inter-device variability. In addition, performance characteristics, computer facilities and details on such practical matters as cost and maintenance are sought. Finally, the BHS protocol provides a grading system of validation which allows comparisons between devices and studies.
منابع مشابه
The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems.
With the increasing manufacture of expensive systems for the measurement of ambulatory blood pressure there is a need for potential purchasers to be able to satisfy themselves that the systems have been evaluated according to agreed criteria. The British Hypertension Society has, therefore, drawn up a protocol of requirements for the evaluation of these devices. This protocol incorporates many ...
متن کاملAccuracy of the SpaceLabs 90207, Novacor DIASYS 200, Del Mar Avionics Pressurometer IV and Takeda TM-2420 ambulatory systems according to British and American criteria.
Ambulatory blood pressure measurement, which has been confined to research for many years, is now an accepted investigation in clinical practice [ l ] . In an effort to ensure that the devices meet the requirements of clinical practice the British Hypertension Society (BHs) has published a comprehensive protocol for the evaluation of blood pressure measuring devices with special reference to am...
متن کاملThe British Hypertension kociety protocol for the evaluation of blood preskure measuring devices
Michael de Swiet*§, Paul L. ~adfie~dq, Douglas G. AltmanE, Martin Blandg, Andrew k oatss and Neil Atkins . Ba-und: With the increasing market~ng of automated and semi-automated devices for the measurement of blood pressuk, there is a need for potential pudhasen to be able to satisfy themselves that such dhices have been evaluated according to agreed criteria. To fulfil this need, the ~ritisk Hy...
متن کاملValidation requirements for ambulatory blood pressure measuring systems.
The increasing application of ambulatory blood pressure measurement in clinical practice has stimulated the manufacture of a large number of ambulatory systems which must be independently validated. The British Hypertension Society protocol for the evaluation of blood pressure measuring devices has now been used to evaluate eight ambulatory systems. Based on this experience recommendations are ...
متن کاملThe need for a standardized protocol for validating non-invasive ambulatory blood pressure measuring devices.
Increasing interest in ambulatory blood pressure measurement has resulted in the proliferation of non-invasive measurement systems. This paper discusses the problems associated with validation of these systems. There is an urgent requirement for a standardized protocol for validation of ambulatory systems which is practicable, universally applicable and which is acceptable to investigators, pub...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of hypertension. Supplement : official journal of the International Society of Hypertension
دوره 8 7 شماره
صفحات -
تاریخ انتشار 1990