Influence of geometric and hemodynamic parameters on aneurysm visualization during three-dimensional rotational angiography: an in vitro study.

نویسندگان

  • Ulrike U Ernemann
  • Eckart Grönewäller
  • Frank B Duffner
  • Oezlem Guervit
  • Joerg Claassen
  • Martin D Skalej
چکیده

BACKGROUND AND PURPOSE Aneurysm depiction with three-dimensional (3D) rotational angiography is influenced by investigator-defined parameters such as image acquisition and contrast agent injection and by the hemodynamic pattern in the parent artery and aneurysm. To assess the impact of the geometric configuration of parent artery and aneurysm on the 3D visualization of saccular aneurysms, we studied silicone aneurysm models under pulsatile-flow conditions. METHODS Rotational angiography was performed in three bifurcation and three lateral aneurysm models with ostia of different widths. Three acquisition modalities (5, 8, and 14 seconds in duration, acquisition rate of 10 frames per second) and two techniques for the injection of contrast material (continuous flow and injection with an initial bolus) were applied. 3D reconstructions were obtained with a volume-rendering technique. RESULTS Bifurcation aneurysms were visualized with high accuracy. Filling deficits distant to the inflow zone could be compensated for with the bolus-injection technique, and complete depiction of aneurysm shape was achieved in the 8-second rotation with 20 mL of contrast agent. In lateral aneurysms, the accuracy of 3D reconstructions depended on the width of the ostium. Although rotational studies in wide-necked lateral aneurysms yielded adequate reconstructions, 3D visualization of small-necked aneurysms was incomplete with the preferential depiction of the distal shell, which represents the inflow zone into the aneurysmal lumen. CONCLUSION Contrast agent injection with the initial-bolus technique improved the depiction of aneurysms, compared with the continuous-flow method. Reconstructions of rotational studies of narrow-necked lateral aneurysms yielded incomplete visualization of the aneurysm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low wall shear stress is associated with the rupture of intracranial aneurysm with known rupture point: case report and literature review

BACKGROUND Few previous hemodynamic studies demonstrated the detailed features of rupture point of intracranial aneurysms. The hemodynamic simulation for the case that ruptured during angiography was even rare. In the present study, we studied the hemodynamic characteristics of a posterior communicating artery segment aneurysm that ruptured during angiography and detailed the hemodynamic featur...

متن کامل

بررسی تأثیر روش آرامسازی بنسون بر اوضاع همو دینامیک بیماران تحت آنژیوگرافی عروق کرونر

Introduction: Invasive diagnostic procedures such as coronary angiography, in most cases, are accompanied by stress and anxiety for patients,which may effect on hemodynamic signs. Materials and Methods:This research, as a quasi experimental study, has the objective to determine the influence of applying methods of relaxation on hemodynamic signs in hospitalized 40 patients, experienciny corona...

متن کامل

Role of Magnesium Sulfate in Preventing Vasospasm and Maintaining Hemodynamic Stability in Patients Undergoing Endovascular Coiling for Brain Aneurysm

Introduction: Themaintenance of hemodynamic stability in brain aneurysm surgery has paramount clinical significance in order to prevent vasospasm in the patients with aneurysmal subarachnoid hemorrhage. Regarding this, the present study was conducted to assess the role of magnesium sulfate in preventing vasospasm and maintaining hemodynamic stability during endovascular coiling procedure for br...

متن کامل

Improved Visualization of Intracranial Vessels with Intraoperative Coregistration of Rotational Digital Subtraction Angiography and Intraoperative 3D Ultrasound

INTRODUCTION Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. METHODS We analyzed 3D intraoperative ultrasound in 39 patients wit...

متن کامل

One-Dimensional design of a three-stage axial compressor with Its 3D numerical simulation

The purpose of this study is to design a three-stage axial compressor with identical pressure ratio which makes an adequate pressure ratio and efficiency in design point conditions with rotational velocity of 38000rpm and mass flow rate of 3.2kg/s. First of all, considering some restrictions such as Dehaller number more than 0.7 in all sections of the stator and the rotor, and relative Mach num...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 2003