Corneal Endothelial Characteristics, Central Corneal Thickness, and Intraocular Pressure in a Population of Chinese Age-Related Cataract Patients
نویسندگان
چکیده
PURPOSE To describe corneal endothelial characteristics, central corneal thickness, and intraocular pressure in a population of Chinese age-related cataract patients and to determine the effects of age, gender, hypertension, and body mass index (BMI). METHODS 1551 eyes were examined preoperatively. The parameters measured were endothelial cell density (CD), average cell area (CA), coefficient of variation (CV), cell hexagonality (HEX), central corneal thickness (CCT), intraocular pressure (IOP), and axial length (AL). RESULTS There were significant differences in CV and BMI between genders. There was a significant decrease in CD, CCT, and IOP and, conversely, an increase in CA and BMI with increasing age. The patients who suffered from hypertension had bigger CA, less CD, and lower HEX than the patients who did not suffer from hypertension. CD has a negative correlation with age and CV and a positive correlation with CCT, CCT has a positive association with CD and IOP, and IOP had a negative relationship with age and a positive relationship with CCT, CA, and HEX. CONCLUSIONS Normative data for the corneal endothelium, central corneal thickness, and intraocular pressure in the normal age-related cataract patients are reported which will serve as a baseline for comparative studies about cataract.
منابع مشابه
بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن
To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملIntraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملComparison of BD Multivisc with the soft shell technique in cases with hard lens nucleus and Fuchs endothelial dystrophy.
PURPOSE To compare the efficacy of 2.5% sodium hyaluronate (BD Multivisc) with the soft shell technique in reducing corneal endothelial cell damage during cataract phacoemulsification in patients with hard lens nucleus (3+) and cornea guttata. METHODS Thirty patients (37 eyes) scheduled for cataract surgery at Department of Ophthalmology and Visual Sciences, University Hospital San Raffaele, ...
متن کاملSafety of besifloxacin ophthalmic suspension 0.6% as a prophylactic antibiotic following routine cataract surgery: results of a prospective, parallel-group, investigator-masked study
BACKGROUND The purpose of this study was to evaluate the safety and tolerability of besifloxacin ophthalmic suspension 0.6% compared with moxifloxacin ophthalmic solution 0.5%, when used for infection prophylaxis following uncomplicated phacoemulsification clear cornea surgery using sutureless corneal incision. METHODS This prospective, two-site, parallel-group, investigator-masked clinical s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017