Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors

نویسندگان

  • Y. F. Du
  • Z. He
  • G. F. Knoll
  • D. K. Wehe
  • W. Li
چکیده

A CZT Compton Camera (CCC) is being built using two three-dimensional (3-D) position-sensitive CZT detectors. Expected system performance was analyzed by analytical and Monte Carlo approaches. Based on the measurement of detector energy and position resolution, the expected angular resolution is &33 and &23 for a $303 FOV for 511 keV and 1 MeV c-rays, respectively. The intrinsic e$ciency for a point source 10 cm from the "rst detector surface ranges from 1.5]10~4 to 8.8]10~6 for 500 keV}3 MeV. ( 2001 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Progress in the Development of CdZnTe Unipolar Detectors for Different Anode Geometries and Data Corrections

CdZnTe detectors have been under development for the past two decades, providing good stopping power for gamma rays, lightweight camera heads and improved energy resolution. However, the performance of this type of detector is limited primarily by incomplete charge collection problems resulting from charge carriers trapping. This paper is a review of the progress in the development of CdZnTe un...

متن کامل

Performance of multi-element CdZnTe detectors

Single-element CdZnTe detectors are limited in size, and therefore efficiency, by the poor hole transport, even with a coplanar grid. We are investigating the possibility of a 27-element (3 × 3 × 3) array using 15 mm × 15 mm × 15 mm elements for gamma-ray energies to 10 MeV for NASA planetary missions. We present experimental results for combinations of various size coplanar grid detectors usin...

متن کامل

3-D position sensitive CdZnTe gamma-ray spectrometers

Two 3-D position-sensitive room temperature semiconductor c-ray spectrometers have been built using 1 cm3 cubic CdZnTe crystals. The lateral coordinates of c-ray interaction are obtained from the location of the 11(x)]11(y) pixellated anodes and the depth (z) is obtained from the ratio of the signals coming from the cathode and the anode. Energy spectra from 662keV incident c-rays have been col...

متن کامل

Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers

We present results from two 1 cm3 CdZnTe gamma-ray spectrometers with full 3-D position sensitivity. To our knowledge, these are the "rst reported semiconductor spectrometers that provide independent spectral data for each of over 2000 volume elements. Energy resolutions of 1.5}1.6% FWHM and position resolutions of 0.7]0.7]0.5 mm were obtained at 662 keV gamma-ray energy from the central region...

متن کامل

MEASUREMENT OF DIAGNOSTIC X-RAY SPECTRA USING CdZnTe DETECTOR

INTRODUCTION We directly measured diagnostic X-ray photon spectra produced by a single-phase 2-pulse diagnostic X-ray unit driven at 50 to 100 kV and a few mA(1), a mammographic X-ray unit at 25 to 32 kV and 3 times of 80 mAs(2) and an X-ray computed tomography (CT) scanner at 120 kV and 3 mA(3) have been analyzed. Since detected spectra were distorted by the response of CdZnTe(CZT) detector an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001