Observer variation for radiography, computed tomography, and magnetic resonance imaging of occult hip fractures.

نویسندگان

  • David Collin
  • Dennis Dunker
  • Jan H Göthlin
  • Mats Geijer
چکیده

BACKGROUND Conventional radiography is insufficient for diagnosis in a small but not unimportant number of hip fractures, and secondary imaging with computed tomography (CT) or magnetic resonance imaging (MRI) is warranted. There are no convincing observer variation studies performed for conventional radiography or CT in occult fractures, and no large materials for MRI. PURPOSE To assess observer variation in radiography, CT and MRI of suspected occult, non-displaced hip fractures, and to evaluate to what extent observer experience or patient age may influence observer performance. MATERIAL AND METHODS A total of 375 patients after hip trauma where radiography was followed by CT or MRI to evaluate a suspected occult hip fracture were collected retrospectively from two imaging centers. After scoring by three observers with varying degrees of radiologic experience, observer variation was assessed by using linear weighted kappa statistics. RESULTS For radiography, agreements between the three observers were moderate to substantial for intracapsular fractures, with kappa values in the ranges of 0.56-0.66. Kappa values were substantial for extracapsular fractures, in the ranges of 0.69-0.72. With increasing professional experience, fewer fractures were classified as equivocal at radiography. For CT and MRI, observer agreements were similar and almost perfect, with kappa values in the ranges of 0.85-0.97 and 0.93-0.97. CONCLUSION There were almost perfect observer agreements for CT and MRI in diagnosing non-displaced, occult hip fractures. Observer agreements for radiography were moderate to substantial, and observer experience influenced agreement only at radiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

متن کامل

The Effect of Intra-Canal Posts on Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography in Detection of Vertical Root Fractures

Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics. Cone Beam Computed Tomography (CBCT)  has significantly enhanced image quality compared to digital radiography (DR) and greatly aids the diagnosis of VRFs but, metal artifacts has remained as a problem in VRF detection.  This study evaluated the effect of intra canal posts on the diagnostic accuracy of CBCT and D...

متن کامل

Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review

Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...

متن کامل

Occult Intertrochanteric Fracture Mimicking the Fracture of Greater Trochanter

PURPOSE Occult intertrochanteric fractures are misdiagnosed as isolated greater trochanteric fractures in some cases. We investigated the utility of three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI) in the diagnosis and outcome management of occult intertrochanteric fractures. MATERIALS AND METHODS This study involved 23 cases of greater trochanteric fractures...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta radiologica

دوره 52 8  شماره 

صفحات  -

تاریخ انتشار 2011