Title: Free moving metallic particle detection in GIS

ثبت نشده
چکیده

High reliability of gas insulated switchgear apparatus is diminished by the presence of defects inside the system. The most common defects are due to metallic particles. This defect can be detected by several techniques, one of which is that using acoustic sensors placed on the enclosure. This paper presents the technique to detect metallic particle from the parameters of acoustic signal such as maximum acoustic amplitude and number of pulses, which exceed the specified level of maximum acoustic amplitude at different supply voltage

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dependence of Particle Initiated PD Characteristics on Size and Position of Metallic Particle Adhering to the Spacer Surface in GIS

It is well known that metallic particles reduce the reliability of Gas-Insulated Substation (GIS) equipments by initiating partial discharge (PDs) that can lead to breakdown and complete failure of GIS. This paper investigates the characteristics of PDs caused by metallic particle adhering to the solid spacer. The PD detection and measurement were carried out by using IEC 60270 method with part...

متن کامل

Influence of Free Metallic Particle Dimensions on Its Movement in Three Phase Common Enclosure Gas Insulated Busduct(GIB) Using Charge Simulation Method

In this paper, the trajectories of free conducting particles of various sizes inside a three phase common enclosure Gas Insulated Busduct(GIB) are simulated by solving the nonlinear second order differential equation of particle motion iteratively by using RK 4 Order Method. Compressed Gas Insulated Substations(GIS) consists of a conductor supported by spacers inside of Sulphur hexafluoride gas...

متن کامل

Modelling and Simulation of Trajectories of a Wire Like Particle in a Three Phase Common Enclosure Gas Insulated Busduct (GIB) with Image Charges

Abstract: In recent years, SF6 gas insulated switchgear (GIS) has become more widespread in electrical power substations and GIS rated from 66 to 1100kV are working successfully. The GIS is used in closed vessels, isolated from the atmosphere. This gives it intrinsically high insulation reliability because there is no contact with dirt or contaminates. To assure even better reliability, measure...

متن کامل

Effect of Lightning Impulse Voltage on the Performance of 1-phase Gas Insulated Busduct in the Presence of Metallic Particle Contamination with Sf6/n2 Gas Mixtures

SF6 is the main mode of insulation in a GIS. However, in recent years, the future use of SF6 has been debated throughout the world in spite of it having all the desirable properties of a good insulating and arc quenching medium. Sulfur hexafluoride (SF6) has been used as a gaseous dielectric (insulator) in high voltage equipment since the 1950s. It is now known that SF6 is a potent greenhouse w...

متن کامل

Image processing techniques for metallic object detection with millimetre-wave images

In this paper we present a system for the automatic detection and tracking of metallic objects concealed on moving people in sequences of millimetre-wave images, which can penetrate clothing, plastics and fabrics. The subjects are required to enter one at a time and turn round slowly to ensure complete coverage for the scan. The system employs two distinct stages: detection and tracking. In thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007