Momentum space tomographic imaging of photoelectrons

نویسندگان

  • C Smeenk
  • L Arissian
  • A Staudte
  • D M Villeneuve
  • P B Corkum
چکیده

We apply tomography, a general method for reconstructing 3D distributions from multiple projections, to reconstruct the momentum distribution of electrons produced via strong field photoionization. The projections are obtained by rotating the electron distribution via the polarization of the ionizing laser beam and recording a momentum spectrum at each angle with a 2D velocity map imaging spectrometer. For linearly polarized light, the tomographic reconstruction agrees with the distribution obtained using an Abel inversion. Electron tomography, which can be applied to any polarization, will simplify the technology of electron imaging. The method can be directly generalized to other charged particles.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a momentum microscope for time resolved band structure imaging.

We demonstrate the use of a novel design of a photoelectron microscope in combination to an imaging energy filter for momentum resolved photoelectron detection. Together with a time resolved imaging detector, it is possible to combine spatial, momentum, energy, and time resolution of photoelectrons within the same instrument. The time resolution of this type of energy analyzer can be reduced to...

متن کامل

Partitioning of the linear photon momentum in multiphoton ionization.

The balance of the linear photon momentum in multiphoton ionization is studied experimentally. In the experiment argon and neon atoms are singly ionized by circularly polarized laser pulses with a wavelength of 800 and 1400 nm in the intensity range of 10(14)-10(15)  W/cm2. The photoelectrons are measured using velocity map imaging. We find that the photoelectrons carry linear momentum correspo...

متن کامل

Photon-momentum transfer in multiphoton ionization and in time-resolved holography with photoelectrons

In most models and theoretical calculations describing multiphoton ionization by infrared light, the dipole approximation is used. This is equivalent to setting the very small photon momentum to zero. Using numerical solutions of the two-dimensional (2-D) time-dependent Schrödinger equation for one electron (H-like) systems, we show that, for linear polarization, the radiation pressure on photo...

متن کامل

Evaluation of the Association of Sinus Mucosal Thickening with Dental and Periodontal Status Using Cone Beam Computed Tomographic Imaging

Introdouction: Cone Beam Computed Tomography (CBCT) is a relatively new three-dimensional imaging technology, which has been widely used in dental and maxillofacial imaging. Materials and methods: CBCT scans of 506 maxillary sinuses of 253 individuals (39.9% male and 60.1% female) were evaluated retrospectively for assessing the relationship between sinus mucosal thickening (MT) and dental a...

متن کامل

Experimental retrieval of target structure information from laser-induced rescattered photoelectron momentum distributions.

We have measured two-dimensional photoelectron momentum spectra of Ne, Ar, and Xe generated by 800-nm, 100-fs laser pulses and succeeded in identifying the spectral ridge region (back-rescattered ridges) which marks the location of the returning electrons that have been backscattered at their maximum kinetic energies. We demonstrate that the structural information, in particular the differentia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009