Iron specificity of a biosensor based on fluorescent pyoverdin immobilized in sol-gel glass

نویسندگان

  • Michael F Yoder
  • William S Kisaalita
چکیده

Two current technologies used in biosensor development are very promising: 1. The sol-gel process of making microporous glass at room temperature, and 2. Using a fluorescent compound that undergoes fluorescence quenching in response to a specific analyte. These technologies have been combined to produce an iron biosensor. To optimize the iron (II or III) specificity of an iron biosensor, pyoverdin (a fluorescent siderophore produced by Pseudomonas spp.) was immobilized in 3 formulations of porous sol-gel glass. The formulations, A, B, and C, varied in the amount of water added, resulting in respective R values (molar ratio of water:silicon) of 5.6, 8.2, and 10.8. Pyoverdin-doped sol-gel pellets were placed in a flow cell in a fluorometer and the fluorescence quenching was measured as pellets were exposed to 0.28 - 0.56 mM iron (II or III). After 10 minutes of exposure to iron, ferrous ion caused a small fluorescence quenching (89 - 97% of the initial fluorescence, over the range of iron tested) while ferric ion caused much greater quenching (65 - 88%). The most specific and linear response was observed for pyoverdin immobilized in sol-gel C. In contrast, a solution of pyoverdin (3.0 μM) exposed to iron (II or III) for 10 minutes showed an increase in fluorescence (101 - 114%) at low ferrous concentrations (0.45 - 2.18 μM) while exposure to all ferric ion concentrations (0.45 - 3.03 μM) caused quenching. In summary, the iron specificity of pyoverdin was improved by immobilizing it in sol-gel glass C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Leaching Behavior of a Fluorescent Pyoverdin Immobilized in Sol-Gel Glass

The leaching behavior of fluorescent siderophore, pyoverdin (iron biosensor), immobilized in acid-catalyzed sol-gel glass is examined. By varying the R value (molar ratio of water:silicon), three different formulations of pyoverdindoped sol-gel glass pellets (R = 5.6, 8.2, 10.8) were made with tetramethyl orthosilicate (TMOS). At three different aging times (2, 4, and 6 weeks), 7-day leaching e...

متن کامل

Sol–gel-derived thick-film conductometric biosensor for urea determination in serum

A conductometric urea biosensor based on sol–gel-immobilized urease on a screen-printed inter-digitated array (IDA) electrode has been developed. The screen-printed thick-film IDA electrode has proven to be an excellent conductometric transducer in which the admittance signal was dominated by the conductance signal and the resulting dynamic range was wide enough to be employed for the construct...

متن کامل

Synthesis, characterization and photocatalytic properties of Iron oxide nanoparticles synthesized by sol-gel autocombustion with ultrasonic irradiation

Iron oxide (Fe2O3) nanoparticles were prepared by combination of sol-gel autocombustion and ultrasonic irradiation. The XRD pattern reveals that the crystallite size of sample is 36.7 nm and the phase identification shows hematite, syn has been crystalized. The morphology of the sample investigated by FESEM showed that particle size of the sample was about 76 nm. The optic...

متن کامل

An Amperometric Nitrite Biosensor Based on the Bioelectrocatalysis of Hemoglobin Incorporated in Sol-gel Film

A highly sensitive, fast and stable biosensor for determination of nitrite was developed using hemoglobin immobilized on a poly (N-isopropylacyamide-co-3methacryloxypropyltrimethoxysilane) (PNM) modified glass carbon electrodes. The matrix provided a biocompatible microenvironment for retaining the native structure and activity of the entrapped hemoglobin. Nitrite could be reduced by the electr...

متن کامل

Modified Glass Carbon Electrode (GCE) Electropolymerized Polypyrrole Nanofibers with Hemoglobin (Hb) Film as a Unique Biosensor for Nitrite Determination

Abstract: In this study, we were investigated behavior the electrochemical reductionof nitrite at a hemoglobin (Hb) immobilized on glass carbon electrode (GCE) containingpolypyrol nanofiber (ppy) films. Polypyrrole (PPy) nanofibers have been constructed onGCE applying electrochemical technique, and can to deposit diverse polymers onminiaturized electrodes with this commo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011