Geometric calibration of a stationary digital breast tomosynthesis system based on distributed carbon nanotube X-ray source arrays

نویسندگان

  • Changhui Jiang
  • Na Zhang
  • Juan Gao
  • Zhanli Hu
چکیده

Stationary digital breast tomosynthesis (sDBT) with distributed X-ray sources based on carbon nanotube (CNT) field emission cathodes has been recently proposed as an approach that can prevent motion blur produced by traditional DBT systems. In this paper, we simulate a geometric calibration method based on a proposed multi-source CNT X-ray sDBT system. This method is a projection matrix-based approach with seven geometric parameters, all of which can be obtained from only one projection datum of the phantom. To our knowledge, this study reports the first application of this approach in a CNT-based multi-beam X-ray sDBT system. The simulation results showed that the extracted geometric parameters from the calculated projection matrix are extremely close to the input values and that the proposed method is effective and reliable for a square sDBT system. In addition, a traditional cone-beam computed tomography (CT) system was also simulated, and the uncalibrated and calibrated geometric parameters were used in image reconstruction based on the filtered back-projection (FBP) method. The results indicated that the images reconstructed with calibrated geometric parameters have fewer artifacts and are closer to the reference image. All the simulation tests showed that this geometric calibration method is optimized for sDBT systems but can also be applied to other application-specific CT imaging systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distributed source x-ray tube technology for tomosynthesis imaging.

Tomosynthesis imaging requires projection images from different viewing angles. Conventional systems use a moving xray source to acquire the individual projections. Using a stationary distributed x-ray source with a number of sources that equals the number of required projections, this can be achieved without any mechanical motion. Advantages are a potentially faster image acquisition speed, hi...

متن کامل

Development of a Stationary Chest Tomosynthesis System Using Carbon Nanotube X-ray Source Array

Jing Shan: Development of a stationary chest tomosynthesis system using carbon nanotube x-ray source array (Under the direction of Otto Zhou) X-ray imaging system has shown its usefulness for providing quick and easy access of imaging in both clinic settings and emergency situations. It greatly improves the workflow in hospitals. However, the conventional radiography systems, lacks 3D informati...

متن کامل

Stationary digital breast tomosynthesis with distributed field emission X-ray tube.

Tomosynthesis requires projection images from different viewing angles. Using a distributed x-ray source this can be achieved without mechanical motion of the source with the potential for faster image acquisition speed. A distributed x-ray tube has been designed and manufactured specifically for breast tomosynthesis. The x-ray tube consists of 31 field emission x-ray sources with an angular ra...

متن کامل

Breast tomosynthesis reconstruction with a multi-beam x-ray source

As a new three-dimensional breast imaging technique, breast tomosynthesis allows the reconstruction of an arbitrary set of planes in the breast from a limited-angle series of x-ray projection images. The breast tomosynthesis technique has been demonstrated as promising to improve early breast cancer detection. This paper represents a preliminary phantom study and computer simulation results of ...

متن کامل

TU-E-217BCD-11: Evaluating the Performance of a Stationary Digital Breast Tomosynthesis System.

PURPOSE In conventional Digital Breast Tomosynthesis (DBT) systems a single x-ray source moves over a limited angle arc. This leads to motion blurring in the projection images associated with x-ray source motion and total scan times. We have developed a stationary DBT (s-DBT) system which forgoes a rotating source for an array of carbon nanotube (CNT) based x-ray sources. Here we report the res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017