Randomized multicenter comparison of 2 IMZ and 4 TPS screw implants supporting bar-retained overdentures in 425 edentulous mandibles.

نویسندگان

  • Jochen Mau
  • Alexandra Behneke
  • Nikolaus Behneke
  • Claus Udo Fritzemeier
  • German Gomez-Roman
  • Bernd d'Hoedt
  • Hubertus Spiekermann
  • Volker Strunz
  • Mei Yong
چکیده

PURPOSE Two treatment concepts for implant-supported bar retention of mandibular overdentures-2 intramobile cylinder (IMZ) implants and a Dolder bar and 4 titanium plasma-sprayed (TPS) screw implants and an angulated bar-were compared in a randomized controlled clinical trial with respect to postprosthetic efficacy and safety. MATERIALS AND METHODS Four hundred twenty-five patients with edentulous mandibles were enrolled; 212 were randomized to TPS implants (control group) and 213 to IMZ implants (test group). Endpoints were occurrences of postprosthetic integration deficiency (ID), functional deficiency (FD), and complications. The trial was sized to detect a 10% difference in 5-year ID-free postprosthetic system lifetime with a power of 80%. RESULTS With 340 protocol-completed cases, the trial achieved its predetermined power. The 2 systems did not show statistically significant differences in occurrences of postprosthetic ID and FD; 5-year occurrence-free postprosthetic system lifetime probabilities were estimated as 42.5% with IMZ and 42.8% with TPS, for ID; and as 82.6% with IMZ and 87.2% with TPS, for FD. However, at 3 to 6 months after surgery, mean Periotest values were significantly higher (P = .0001 without adjustment) with IMZ implants (5.6, SD 4.2) than with TPS implants (0.8, SD 4.3). TPS implants showed a higher incidence of inflammation and recession, while IMZ implants had a higher incidence of implant fracture after functional loading. DISCUSSION The system-wise approach overcomes potential bias with implant-wise analyses. A combination of radiographic and clinical criteria distinguishes between desirable integration and functional anchorage. The in situ survival rates at 5 years in this study (95% for IMZ, 92% for TPS) match rates reported in the literature. CONCLUSION This study demonstrated equivalent efficacy of 2 IMZ cylinders and 4 TPS screws in implant-supported, bar-retained mandibular overdentures and indicated a higher rate of complications with the TPS screw implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transmandibular implant versus intramobile cylinder implants: a randomized, prospective clinical trial.

A randomized, controlled clinical trial was conducted to compare two different implant treatment modalities for edentulous patients with severely resorbed mandibles. In one modality (the IMZ group), two intramobile cylinder implants were placed, connected by a Dolder bar and provided with an overdenture, and in the other (the TMI group), a transmandibular implant with a triple bar and cantileve...

متن کامل

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

متن کامل

A clinical comparison of prosthetic complications of implant-supported overdentures with different attachment systems.

OBJECTIVES The objective of this clinical study was to evaluate the prosthetic complications of patients with 2 to 4 implants splinted with a round bar or with 2 to 4 unsplinted implants with ball attachments during the follow-up period. METHODS A total of 26 patients were included in this study. Patients were randomly provided with a round bar or with ball attachments that were used to retai...

متن کامل

Comparison of prefabricated and custom-made bars used for implant-retained mandibular complete overdentures.

PURPOSE To compare prefabricated and custom-made bars used for implant-retained mandibular complete overdentures. MATERIALS Ten completely edentulous patients were selected for replacement with dental implants. Each patient received 2 (press-fit) dental implants, 1 implant on each side in the canine regions of the mandible. The implants were left submerged (unloaded) for a healing osseointegr...

متن کامل

Mandibular overdentures supported by two Brånemark, IMZ or ITI implants: a 5-year prospective study.

OBJECTIVES The aim of this prospective comparative study was to evaluate the survival rate and the condition of the peri-implant tissues of the IMZ implant system (two-stage cylindertype), the Brånemark implant system (two-stage screwtype) and the ITI implant system (one-stage screwtype) supporting a mandibular overdenture during a 5-year follow-up period. MATERIAL AND METHODS Three groups of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2003