The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

نویسندگان

  • Tina Juul
  • Henning Langberg
  • Flemming Enoch
  • Karen Søgaard
چکیده

BACKGROUND This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. METHODS The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. RESULTS Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC = 0.19-0.25). CONCLUSIONS Intra- and inter-rater reliability ranged from moderate to almost perfect agreement with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement. The significant variability observed suggests that tests like the neck extensor test and the neck flexor muscle endurance test performed in a 45°-upright position are too unstable to be used when evaluating neck muscle performance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی پایایی بین دو آزمونگر و پایایی یک آزمونگر تست بریف بست در ارزیابی تعادل بیماران مبتلا به سکته مغزی: گزارش کوتاه

Background: Impaired balance is one of the most common symptoms that occur after stroke. There are several tests for evaluating balance in neurological disorders. Brief-balance evaluation systems test (Brief-BESTest) is the short version of BESTest that assess the systems contributing to postural control. The purpose of this study was to investigate the inter- and intra-rater reliability of the...

متن کامل

Intra- and inter-rater reliability of neutral head position and target head position tests in patients with and without neck pain

BACKGROUND Cervical proprioception is a common term used in neck rehabilitation, and it is examined using neutral head position (NHP) and target head position (THP) tests. OBJECTIVE To investigate intra- and inter-rater reliability of the NHP and THP tests in patients with neck pain and in healthy controls. METHODS The intra-rater (between-day) and inter-rater (within-day) reliability of th...

متن کامل

The reliability of a 10-test package for patients with prolonged back and neck pain: could an examiner without formal medical education be used without loss of quality? A methodological study

BACKGROUND In the rehabilitation of patients with prolonged back and neck pain, the physical impairment should be assessed. Previous research has exclusively engaged medically educated examiners, mostly physiotherapists. However, less biased evaluations of efforts at rehabilitation might be achieved by personnel standing outside the treatment work itself. Therefore, if medically untrained exami...

متن کامل

Intra and Inter-Rater Reliability and Convergent Validity of FIT-HaNSA in Individuals with Grade П Whiplash Associated Disorder

BACKGROUND Whiplash-Associated Disorders (WAD) are common following a motor vehicle accident. The Functional Impairment Test - Hand, and Neck/Shoulder/Arm (FIT-HaNSA) assesses upper extremity physical performance. It has been validated in patients with shoulder pathology but not in those with WAD. OBJECTIVES Establish the Intra and inter-rater reliability and the known-group and construct val...

متن کامل

Intra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy

Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013