Reliability and validity of a wireless microelectromechanicals based system (keimove™) for measuring vertical jumping performance.

نویسندگان

  • Bernardo Requena
  • Inmaculada García
  • Francisco Requena
  • Eduardo Saez-Saez de Villarreal
  • Mati Pääsuke
چکیده

UNLABELLED The aim of this study was to determine the validity and reliability of a microelectromechanicals (MEMs) based system (Keimove™) in measuring flight time and takeoff velocity during a counter-movement jump (CMJ). As criterion reference, data of a high- speed camera (HSC) and a force-platform (FP) synchronized with a linear position transducer (LPT) was used. Thirty professional soccer players completely familiarized with the CMJ technique performed three CMJs. The second and third trials were used for further analysis. The Keimove™ system, the HSC and the FP synchronized with the LPT (FP+LPT) simultaneously measured the CMJ performance. During each repetition, the Keimove™ system registered flight time and velocity at takeoff. At the same time and as criterion reference, both the HSC and the FP recorded the flight time while the LPT+FP registered the velocity at takeoff. Pearson correlation coefficients for the flight time were high (r = 0.99; p < 0.001) when Keimove™ system was compared with the HSC or the FP+LPT, respectively. For the velocity at takeoff variable, the Pearson r between the Keimove™ system and the FP+LPT was lower although significant at the 0.05 level. No significant differences in mean values were observed for flight times and velocity at takeoff between the three devices. Intraclass correlations and coefficients of variation between trials were similar and ranged between 0.92-0.97 and 2.1-7.4, respectively. In conclusion, the Keimove™ system represents a valid and reliable instrument to measure velocity at takeoff and flight time during CMJ testing. Thus, this MEMs-based system will offer a portable, cost-effective tool for the assessment CMJ performance. KEY POINTS The Keimove™ system is composed of specific software and a wireless MEMs-based device designed to be attached at the lumbar region of the athlete.The Keimove™ system is a mechanically valid and reliable instrument in measuring flight time and velocity at takeoff during CMJ.The validity of the Keimove™ system was determined by comparing its mean flight time and velocity at takeoff with data obtained simultaneously with both a high-speed camera and a force platform synchronized with a linear position transducer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity and Reliability of Methods for Testing Vertical Jumping Performance

The validity and reliability of the jumping ergometer method for evaluating performance in two-legged vertical countermovement and serial rebound jumps were investigated. The internal segmental and nonvertical energy flow components for drop jumps were also studied. The exact dynamic equations governing the jumping motion in three dimensions were derived and used together with the approximate r...

متن کامل

Performance Analysis of Wireless Cooperative Networks with Iterative Incremental Relay Selection

In this paper, an iterative incremental relay selection (IIRS) scheme is considered for wireless cooperative networks in order to increase the reliability of transmission. Different from the conventional incremental relay selection which incrementally selects a best relay for only one iteration; the IIRS scheme iteratively applies the incremental relaying and relay selection processes. To evalu...

متن کامل

Design and fabrication of three axes accelerometer

Technology can provide safety in physical practices and improving the performance of these activities, so manufacturing of equipments for these purposes has been considered widely. The aim of the present paper was design and fabrication of three-axis accelerometer. hree acceleration sensors, three gyroscopes for angular velocity measurement, a microcontroller for converting analog data to ...

متن کامل

Reliability and Validity of Bedside Version of Persian WAB (P-WAB-1)

Introduction: In this study, we reported the reliability and validity of Bedside version of Persian WAB (P-WAB-1) adapted from Western Aphasia Battery (WAB-R)1,2. P-WAB-1 is a clinical linguistic measuring tool to determine severity and type of aphasia in brain damaged patients based on Aphasia Quotient (AQ) as a functional measure. For the purposes of a quick clinical screening of aphasia in...

متن کامل

Toward an energy efficient PKC-based key management system for wireless sensor networks

Due to wireless nature and hostile environment, providing of security is a critical and vital task in wireless sensor networks (WSNs). It is known that key management is an integral part of a secure network. Unfortunately, in most of the previous methods, security is compromised in favor of reducing energy consumption. Consequently, they lack perfect resilience and are not fit for applications ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of sports science & medicine

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2012