Detection of pulmonary embolism with hyperpolarized 3He MRI: a comparison of pO2-based and susceptibility-based techniques
نویسندگان
چکیده
Introduction: Pulmonary embolism (PE) is a common, elusive, and deadly condition, with an annual incidence of over 600,000 cases, with 200,000 deaths, in the United States alone. In recent years, hyperpolarized He MRI has been applied with the aim of PE diagnosis. To date, two techniques have been proposed. The first technique measures the pulmonary partial pressure of oxygen by utilizing the fact that the alveolar partial pressure of oxygen is elevated in the region where blood flow is blocked by PE (1). The second technique uses gadolinium (Gd) to modify the magnetic susceptibility difference between the lung airway and tissue, and this modification is recorded through the phase of the HP He MRI signal (2). In this work, we present a comparison of the two techniques by performing an in-vivo experiment on a pig model with simulated pulmonary embolus. Methods: The in-vivo animal experiment was conducted under a protocol approved by the Animal Use Committee at the University of Pennsylvania. In the PE experiment, a normal Yorkshire pig (~20kg) was transported to an interventional radiology lab where a balloon catheter was placed in the midportion of the right lower lobar pulmonary artery via passage through the femoral vein and the right atrium of the heart. The size of the balloon (Boston Scientific Corp., Natick, MA) was 9 mm x 2 cm. Arteriography was performed through the balloon catheter guide wire lumen to confirm the position of the balloon. The pig was then transported to a 1.5T Siemens Sonata MRI scanner for imaging. In the experiment, three measurements were performed in which the pO2 and susceptibility difference were simultaneously measured. First, the balloon was deflated and the animal was in a normal state. A baseline measurement was performed. After the baseline measurement, PE was simulated by inflating the balloon with saline solution until the affected artery was completely occluded. A volume of 15mL Gd was injected through an ear vein by a power injector at the rate of 2.0mL/s; this injection was followed by a saline flush. The second measurement was initiated 10 minutes after the Gd injection. The third measurement was performed after another 15mL Gd was injected to further enhance the susceptibility difference between the airway and lung tissue. In each of the three measurements, a tidal volume of 250 mL, consisting of 50 mL O2 and 200 mL He gas, was administered to the animal by a prototype ventilator. A small flip angle gradient echo sequence, in which eight gradient echoes were generated by inverting the readout gradient in each TR, was used in the three measurements. Three coronal slices in the supine direction were acquired with the following imaging parameters: FOV=240 mm, slice thickness=25 mm, slice spacing=5 mm, TR=15ms, TE1/echo separation=2.08ms/1.42ms, bandwidth: 800Hz/Px, matrix size=64×64, and flip angle ≈ 4.5 degrees. In each measurement, a series of six images was acquired for each echo with delays of 0, 2.880, 10.163, 16.743, 21.323 and 24.203 seconds with respect to the first image to measure oxygen partial pressure (pO2) and oxygen depletion rate (R). Result and Discussion: Figure 1 shows the six raw images of the first echo of the middle slice acquired in the baseline and the second measurements. In the right lower region, where the lobar pulmonary artery was blocked by the balloon, the He MRI signal decayed more quickly. In the same region, elevated pO2 values were observed in the fitting parametric maps. Figure 3 shows the eight echoes acquired for the middle slice (for simplicity, only the odd number of echoes are shown). It should be noted that in the PE region, no obvious differences were observed between the baseline and second measurements. This observation is confirmed in Figure 4, where no significant differences can be seen in the phase maps of the three measurements. Conclusion: In this work, we present a comparison of pO2-based and susceptibility-based hyperpolarized He MRI techniques for the detection of pulmonary emboli in a pig model. The experiment results show that the pO2-based technique is more sensitive than the susceptibility-based technique. The results also suggest that a superparamagnetic intravascular contrast agent may be needed to introduce the measurable magnetic susceptibility difference if the susceptibility-based technique is applied for the detection of PE. References: 1) Aman Jalali et al., Mag Res Med, 51:291–298 (2004) 2) Ivan E. Dimitrov et al., J. Mag Res Imag, 21:149–155 (2005) Phase (degree):144±60 Phase (degree):145±58 Phase (degree): 142±63 360
منابع مشابه
Functional MRI of the Lung
Imaging of the pulmonary parenchyma represents a unique challenge for MRI. Limited signal is caused by low proton density, susceptibility artefacts, and physiological motion (cardiac pulsation, respiration). Improvements in MRI techniques have extended the potential for investigations of pulmonary parenchymal disease with the evaluation of lung perfusion. More recently inhalation of non proton-...
متن کاملDiagnosis of thromboembolic disease: Combined ventilation perfusion lung scan and compression ultrasonography
The clinical management of pulmonary embolism and deep venous thrombosis of the legs are similar and requires prolonged anticoagulation therapy. The standard diagnostic approach in patients suspected of pulmonary embolism is ventilation-perfusion (V/Q) lung scan and compression ultrasonography to detect deep venous thrombosis. This retrospective study analyzed the role of V/Q lung scan an...
متن کاملProton and hyperpolarized helium magnetic resonance imaging of radiation-induced lung injury in rats.
PURPOSE To assess the usefulness of hyperpolarized helium (3He) MRI, including apparent diffusion coefficient measurements, in the detection and evaluation of radiation-induced lung injury in rats. METHODS AND MATERIALS Female Fischer-344 rats were treated to the right lung with fractionated dose of 40 Gy (5 x 8 Gy) using 4-MV photons. Conventional proton (1H) and hyperpolarized (3He) MRI wer...
متن کاملCombined Radionuclide Phlebography and V/Q scan in the assessment of iliac vein thrombosis and pulmonary embolism – A case report establishing a cause and effect relationship
Deep vein thrombosis (DVT) is an important life threatening condition that is difficult to diagnose, particularly in the early stages. Looking for DVT in lower limb can be considered ancillary in suspected cases of pulmonary embolism (PE) indirectly highlighting a cause and effect relationship of a single disease (i.e cause being DVT and effect is the assault on the lung vasculature). Prompt an...
متن کاملQuantification of lung microstructure with hyperpolarized 3He diffusion MRI.
The structure and integrity of pulmonary acinar airways and their changes in different diseases are of great importance and interest to a broad range of physiologists and clinicians. The introduction of hyperpolarized gases has opened a door to in vivo studies of lungs with MRI. In this study we demonstrate that MRI-based measurements of hyperpolarized (3)He diffusivity in human lungs yield qua...