Using King Vision video laryngoscope with a channeled blade prolongs time for tracheal intubation in different training levels, compared to non-channeled blade

نویسندگان

  • Marc Kriege
  • Christian Alflen
  • Ruediger R Noppens
چکیده

PURPOSE It is generally accepted that using a video laryngoscope is associated with an improved visualization of the glottis. However, correctly placing the endotracheal tube might be challenging. Channeled video laryngoscopic blades have an endotracheal tube already pre-loaded, allowing to advance the tube once the glottis is visualized. We hypothesized that use of a channel blade with pre-loaded endotracheal tube results in a faster intubation, compared to a curved Macintosh blade video laryngoscope. METHODS After ethical approval and informed consent, patients were randomized to receive endotracheal Intubation with either the King Vision® video laryngoscope with curved blade (control) or channeled blade (channeled). Success rate, evaluation of the glottis view (percentage of glottic opening (POGO), Cormack&Lehane (C&L)) and intubating time were evaluated. RESULTS Over a two-month period, a total of 46 patients (control n = 23; channeled n = 23) were examined. The first attempt success rates were comparable between groups (control 100% (23/23) vs. channeled 96% (22/23); p = 0.31). Overall intubation time was significantly shorter with control (median 40 sec; IQR [24-58]), compared to channeled (59 sec [40-74]; p = 0.03). There were no differences in glottis visualization between groups. CONCLUSION Compared with the King Vision channeled blade, time for tracheal intubation was shorter with the control group using a non-channeled blade. First attempt success and visualization of the glottis were comparable. These data do not support the hypothesis that a channeled blade is superior to a curved video laryngoscopic blade without tube guidance. TRIAL REGISTRATION ClinicalTrials.gov NCT02344030.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative evaluation of the Airtraq and King Vision video laryngoscope as an intubating aid in adult patients.

Airtraq has been shown to improve ease of intubation in patients with normal and difficult airway. King Vision video laryngoscope is a newly introduced intubating device with an attached monitor. We here hypothesized that the King Vision video laryngoscope with channeled blade performs better during intubation as compared to Airtraq. In this study, we performed a comparison between the King Vis...

متن کامل

Evaluation of the success rate and quality of teaching of tracheal intubation to medical students by using video laryngoscope

Background: Training of airway management and tracheal intubation skill in emergencies for resuscitation of patients are basic skills for medical students. However, the success rate of beginners in this skill is low. Video laryngoscopes are new devices that can increase the success of endotracheal intubation training. Methods: This clinical trial was conducted with 30 medical students who came...

متن کامل

Transfer of skills and comparison of performance between king vision® video laryngoscope and macintosh blade following an AHA airway management course

BACKGROUND To potentially optimize intubation skill teaching in an American Heart Association® Airway Management Course® for novices, we investigated the transfer of skills from video laryngoscopy to direct laryngoscopy and vice versa using King Vision® and Macintosh blade laryngoscopes respectively. METHODS Ninety volunteers (medical students, residents and staff physicians) without prior in...

متن کامل

Case Report: Double lumen tube insertion in a morbidly obese patient through the non-channelled blade of the King Vision ™ videolaryngoscope

We describe the insertion of the double lumen endobronchial tube (DLT) using a non-channeled standard blade of the King Vision (TM) videolaryngoscope for one lung ventilation (OLV) in a morbidly obese patient with a predicted difficult airway, severe restrictive pulmonary function, asthma, and hypertension. The patient was scheduled for a video-assisted thoracoscopic lung biopsy. The stylet of ...

متن کامل

Case Report: Double lumen tube insertion in a morbidly obese patient through the non-channelled blade of the King Vision videolaryngoscope [version 4; referees: 2 approved]

We describe the insertion of the double lumen endobronchial tube (DLT) using a non-channeled standard blade of the King Vision videolaryngoscope for one lung ventilation (OLV) in a morbidly obese patient with a predicted difficult airway, severe restrictive pulmonary function, asthma, and hypertension. The patient was scheduled for a video-assisted thoracoscopic lung biopsy. The stylet of the D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017