Determination of Low Levels of Lead in Beer Using Solid-Phase Extraction and Detection by Flame Atomic Absorption Spectrometry

نویسندگان

  • Vanessa N. Alves
  • Simone S. O. Borges
  • Waldomiro B. Neto
  • Nívia M. M. Coelho
چکیده

In this study, a method for the determination of low concentrations of lead in beer samples using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry (FAAS) was developed. Moringa oleifera seeds were used as a biosorbent material. Chemical and flow variables of the online preconcentration system, such as sample pH, preconcentration flow rate, eluent flow rate, eluent concentration, particle size, and sorbent mass, were studied. The optimum extraction conditions were obtained using a sample pH of 6.0, sample flow rate of 6.0 mL min(-1), 63.0 mg of sorbent mass, and 2.0 mol L(-1) HNO(3) at a flow rate of 2.0 mL min(-1) as the eluent. With the optimized conditions, the preconcentration factor, precision, detection limit, consumption index, and sample throughput were estimated as 93, 0.3% (10.0 μg L(-1), n = 7), 7.5 μg L(-1), 0.11 mL, and 23 samples per hour, respectively. The method developed was successfully applied to beer samples and recovery tests, with recovery ranging from 80% to 100%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination

The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Evaluation of two different extraction techniques on determination of 〖Pb〗^(+2) contents of wastes of dye manufacturing industries

Extraction of trace amounts of toxic heavy metals from complicated environmental matrixes is a  challenging task. The aim of this investigation is the comparison of the extraction efficiencies and other related experimental variables ( chemicals, effect of pH, potential interfering ions) on the determination of inorganic lead ( ) which is present in waste water of dye industries. Compared techn...

متن کامل

Determination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination

Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011