Magnetic field strengths in the hot spots of 3 C 33 and 3 C 111

نویسندگان

  • M. J. Hardcastle
  • M. Birkinshaw
  • D. M. Worrall
چکیده

We report on ROSAT HRI observations of the nearby powerful radio galaxies 3C 33 and 3C 111, which both have detected optical hot spots. We find nuclear X-ray sources in both objects, but no X-ray emission from the hot spots. This confirms the presence of a high-energy cutoff in the spectrum of synchrotron-emitting electrons. Since these electrons necessarily scatter the synchrotron photons by the inverse-Compton process, our upper limits on the X-ray fluxes of the hot spots allow us to set lower limits of a few nanotesla on their magnetic flux density, close to or greater than the fields implied by equipartition of energy between radiating particles and magnetic field.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Strengths and Exposure Durations of Magnetic Field on Seeds Germination of Catharanthus roseus cv. ‘Acillata’

Magnetic field  improved germination parameters. The germination of Catharanthus roseus seeds is lost under salinity conditions. The effect of different strengths of magnetic field and exposure durations on the germination of C. roseus seeds under salinity conditions (19 mS cm-1) were investigated. The experiment was conducted  with factorial arrangement based on a completely randomized design ...

متن کامل

Chandra Observations of Cygnus A: Magnetic Field Strengths in the Hot Spots of a Radio Galaxy

We report X-ray observations of the powerful radio galaxy Cygnus A with the Chandra X-Ray Observatory. This Letter focuses on the radio hot spots, all four of which are detected in X-rays with a very similar morphology to their radio structure. X-ray spectra have been obtained for the two brighter hot spots (A and D). Both are well described by a power law with photon index absorbed by the Gala...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Hot tensile properties of 9Cr-2WVTa reduced-activation ferritic/martensitic steel

Reduced-activation ferritic/martensitic steels have been developed by replacing molybdenum by tungsten and niobium by tantalum in commercial elevated-temperature Cr–Mo steels to reduce half-life of radioactive isotopes. The objective of this study was to investigate tensile properties of a reduced-activation ferritic/martensitic steel (9Cr-2WVTa) in normalized-tempered (NT) and quenched-tempere...

متن کامل

Magnetic Field Strengths in the Hot Spots and Lobes of Three Powerful Fanaroff-riley Type Ii Radio Sources

We have made deep Chandra observations of three powerful Fanaroff-Riley type II (FR II) radio sources: two quasars (3C 263 and 3C 351) and one radio galaxy (3C 330). X-ray emission from hot spots and lobes, as well as from the active nucleus, is detected in each source. We model the hot spots’ synchrotron spectra using VLA, BIMA, and Hubble Space Telescope data. In 3C 263 and 3C 330, the hot sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997