Influence of shade and irradiation time on the hardness of composite resins.

نویسندگان

  • Alvaro Della Bona
  • Vinícius Rosa
  • Dileta Cecchetti
چکیده

This study tested the following hypotheses: 1. increasing light irradiation time (IT) produces greater values of superficial hardness on different depths (0 and 3 mm); and 2. a dark shade composite (A3) needs longer IT than a light shade composite (A1) to produce similar hardness. Disk-shaped specimens (n=24 per shade) were fabricated using a 3-mm-thick increment of composite resin (Z100). Specimens were randomly assigned to 3 groups (n=8) according to the IT (400 mW/cm2) at the upper (U) surface: A1-10 and A3-10: 10 s; A1-20 and A3-20: 20 s; A1-40 and A3-40: 40 s. Specimens were stored in black lightproof containers at 37 masculineC for 24 h before indentation in a hardness tester. Three Vickers indentations were performed on the U and lower (L) surfaces of each specimen. The indent diagonals were measured and the hardness value calculated. The results were analyzed statistically by ANOVA and Tukey's test (alpha=0.05). Statistically significant differences were found between U and L surfaces of each composite shade-IT combination (p=0.0001) and among the ITs of same shade-surface combination (p=0.0001), except between groups A1-20U and A1-40U, confirming the study hypothesis 1 and partially rejecting the hypothesis 2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of composite shade, curing time and mode on temperature rise of silorane and methacrylate- based composite resins

Introduction: The present study was performed to evaluate the effects of light-curing modes and shades of methacrylate and silorane-based composite resins on temperature rise during polymerization of composite resins. Materials &Methods: In this in vitro study, ninety composite samples with two types of composite resin - methacrylate-based and a low-shrinkage silorane-based were prepared, in...

متن کامل

Influence of the Distance of the Curing Light Source and Composite Shade on Hardness of Two Composites

This study evaluated the influence of curing tip distance, shade and filler particle size on Vickers microhardness (VHN) of composite resins. Two composites were tested: Filtek Z250 microhybrid (3M ESPE; shades A1 and A3.5) and Filtek Supreme nanofilled (3M ESPE; shades A1B and A3.5B). For each resin, 42 specimens (5 mm in diameter and 2 mm height) were prepared being 21 for each shade. The spe...

متن کامل

Effect of Shade on Immediate and Post-Curing Polymerization Shrinkage of Composite Resin

Background and Aim: Minimizing the polymerization shrinkage of composite resins is a critical goals in composite restorations. Many factors affect polymerization shrinkage. This study aimed to evaluate the effect of composite resin shade on polymerization shrinkage. Materials and Methods: In this in vitro study, 14 composite discs measuring 1.5×8 mm were fabricated. The samples were prepared u...

متن کامل

Effects of 0.2% Chlorhexidine and Re-polishing on the Color Stability of Nanofilled Composite Resins

Introduction: The growing demand for esthetic dental procedures has resulted in the increased development of new restorative composite resins. The success of composite resin restorations depends on their color stability over time. The present study aimed to evaluate the effects of 0.2% chlorhexidine (CHX) and re-polishing on the color stability of nanofilled composite re...

متن کامل

Effect of energy drinks on microhardness of silorane and dimethacrylate-based composite resins

Introduction: Increased consumption of energy drinks has raised concerns about their effects on dental restorations. This study assessed the effects of two energy drinks on the surface microhardness of methacrylate and silorane-based composites after 1-week and 1-month periods. Materials & Methods: In this in-vitro study, 90 cubic samples were prepared from Filtek P90, Filtek Z250 and Filtek Z...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2007