Co-treatment of H2S and toluene in a biotrickling filter

نویسندگان

  • Huub H.J. Cox
  • Marc A. Deshusses
چکیده

Biological treatment is an emerging technology for the treatment of publicly owned treatment works (POTWs) off-gases. Most of POTWs off-gases contain H2S and a wide range of volatile organic compounds (VOCs). Since co-treatment of odors and VOCs in biotrickling filters is a relatively unexplored area, the simultaneous biotreatment of H2S and toluene (as the model VOC) was investigated. The experimental setup included two identical biotrickling filters, one operated at pH 4.5 and the other one was operated at pH 7.0. High concentrations of H2S (up to 170 ppmv) and toluene (up to 2.2 g m−3) were supplied to determine the influence of the pH on the maximum performance. A rapid startup (a few days) was observed for both toluene and H2S removal in the neutral-pH biotrickling filter. In the acidic biotrickling filter, toluene degradation also started immediately but at a lower rate. However, after several weeks of operation, the toluene elimination capacity (EC) at low pH reached a steady value identical to this found in the neutral-pH biotrickling filter. H2S did not affect toluene degradation at concentrations up to 170 ppmv at either pH. At a volumetric load of 100 m3 m−3 h−1, maximum elimination capacities of 70 g toluene m−3 h−1 (at 1.7 g m−3 toluene) and 20 g H2S m−3 h−1 (at 170 ppmv H2S, the highest concentration tested) were observed. Microbial counting and activity measurements indicated the development of different microbial populations in the reactors. In the neutral-pH biotrickling filter, a population developed which had a limited tolerance to low pH. The population in the acidic biotrickling filter showed a broader pH range for removal of H2S and toluene. Overall, the results presented indicated that effective co-treatment of H2S and VOCs can be obtained in a single-stage biotrickling filter. © 2002 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of H2S from Synthetic Waste Gas Streams Using a Biotrickling Filter

The removal of hydrogen sulfide (H2S) from airstreams was studied in a biotrickling filter packed with porous lava as a carrier of Thiobacillus thioparus (DSM5368) with counter current flows of the air and liquid streams. The effect of operating parameters on biotrickling filter performance was studied. Experiments were performed at different empty bed residence times (9-60 sec), and...

متن کامل

Co-treatment of hydrogen sulfide and methanol in a single-stage biotrickling filter under acidic conditions.

Biofiltration of waste gases is cost-effective and environment-friendly compared to the conventional techniques for treating large flow rates of gas streams with low concentrations of pollutants. Pulp and paper industry off-gases usually contain reduced sulfur compounds, such as hydrogen sulfide and a wide range of volatile organic compounds (VOCs), e.g., methanol. It is desirable to eliminate ...

متن کامل

Biomass control in waste air biotrickling filters by protozoan predation.

Two protozoan species as well as an uncharacterized protozoan consortium were added to a toluene-degrading biotrickling filter to investigate protozoan predation as a means of biomass control. Wet biomass formation in 23.6-L reactors over a 77-day period was reduced from 13.875 kg in a control biotrickling filter to 11.795 kg in a biotrickling filter enriched with protozoa. The average toluene ...

متن کامل

Conversion of Full-Scale Wet Scrubbers to Biotrickling Filters for H2S Control at Publicly Owned Treatment Works

Until recently, biological treatment of odors in biofilters or biotrickling filters was thought to require a longer gas contact time than chemical scrubbing, hence bioreactors for air treatment required a larger footprint. This paper discusses the conversion of chemical scrubbers to biological trickling filters. Initially, research was conducted with a laboratory-scale biotrickling filter. An e...

متن کامل

Understanding the limits of H2S degrading biotrickling filters using a differential biotrickling filter

The removal of H2S in high performance biotrickling filters was investigated using a differential biotrickling filter. The differential biotrickling filter was designed to reach high gas velocities through a minature packed bed, in this case a single 4-cm open-pore polyurethane foam cube. External mass transfer was limiting below air velocities of 3000–4000 m h−1, with possible other parameters...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002