Determination of coumarin in fragrance products by capillary gas chromatography with electron capture detection.

نویسنده

  • H H Wisneski
چکیده

A gas chromatographic (GC) method is described for the determination of coumarin in fragrance products. Coumarin was tentatively identified by retention time and confirmed by GC/mass spectrometry. The amount of coumarin was determined by external standard. The method was validated by conducting recovery studies from fortified fragrance products at several concentrations. Recoveries of coumarin ranged from 99 to 110%, with a relative standard deviation of 3.24. The method was used to survey a variety of fragrance products purchased in the metropolitan Washington, DC area, for coumarin. Seventy one percent of the products were found to contain coumarin at concentrations ranging from 0.002 to 0.61%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of musk ambrette, musk xylol, and musk ketone in fragrance products by capillary gas chromatography with electron capture detection.

A gas chromatographic method using a capillary column with electron capture detection was developed for the simultaneous determination of 3 nitromusk fragrance ingredients: musk ambrette (MA), musk xylol (MX), and musk ketone (MK), in fragrance products. The accuracy of the method was determined by recovery of each nitromusk from fortified fragrance products at 3 different concentrations. Recov...

متن کامل

Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study

Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...

متن کامل

Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study

Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...

متن کامل

Determination of plasma bile acids by capillary gas-liquid chromatography-electron capture negative chemical ionization mass fragmentography.

Combined capillary gas-liquid chromatography-electron capture negative chemical ionization mass spectrometry of pentafluorobenzyl ester-TMSi ether derivatives of bile acids and isotope dilution using deuterated internal standards are introduced as a sensitive and selective analysis technique for plasma bile acids. As a result of the high ionization efficiency of pentafluorobenzyl derivatives un...

متن کامل

Determination of Selected Pesticide Residues from Gilgel Gibe (I) Hydroelectric Dam Reservoir and Its Tributaries, Jimma Zone, Ethiopia

In this study, the level of selected organophosphorus and organochlorine pesticide residues from water samples of Gilgle Gibe (I) hydroelectric dam reservoir and its potential tributaries, Jimma zone, Ethiopia, was determined by gas chromatography-electron capture detector (GC-ECD). Low density based dispersive liquid-liquid microextraction (LD-DLLME) using toluene (as extractant) and acetonitr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 84 3  شماره 

صفحات  -

تاریخ انتشار 2001