Exercise-induced acute changes in systolic blood pressure do not alter choroidal thickness as measured by a portable spectral-domain optical coherence tomography device.
نویسندگان
چکیده
PURPOSE To measure choroidal thickness in patients manifesting an acute change in systemic arterial blood pressure using a portable spectral-domain optical coherence tomography device (iVue). METHODS Fifteen patients (15 eyes) undergoing cardiac exercise stress testing were scanned using a portable spectral-domain optical coherence tomography system (iVue). Two scan protocols were used: cross line scan for measuring choroidal thickness and the retina map scan to measure retinal thickness. Each patient was scanned before and within 3 minutes after the stress test. Blood pressure was measured at the same time as the acquisition of the scans. Choroidal thickness was measured from the posterior edge of the retinal pigment epithelium to the choroid-sclera junction at 500-μm intervals up to 1,000 μm temporal and nasal to the fovea. Retinal thickness was measured by an automated software. All choroidal thickness measurements were performed by two independent observers. RESULTS Fifteen patients (15 eyes) with a mean age of 60.6 (±10.4 years) were scanned. There was a significant increase in systolic but not diastolic pressure after stress testing (P < 0.05). The mean choroidal thickness measurements showed no significant difference before and after exercise stress testing (P > 0.05). In addition, there was no significant difference in retinal thickness before and after stress testing measurements (P > 0.05). CONCLUSION There was no change in choroidal thickness or retinal thickness, despite an acute change in the systemic systolic blood pressure induced by exercise.
منابع مشابه
Comparison of Choroidal Thickness in Patients with Diabetes by Spectral-domain Optical Coherence Tomography
PURPOSE To evaluate choroidal thickness in diabetes patients using spectral-domain optical coherence tomography. METHODS We examined 203 eyes of 203 diabetic participants and 48 eyes of 48 healthy controls. The choroidal thickness at the foveal lesion was measured by enhanced-depth imaging optical coherence tomography. The participants were grouped according to diabetic retinopathy grade: no ...
متن کاملComparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography
Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...
متن کاملEvaluation of choroidal and retinal thickness measurements in adult hemodialysis patients using spectral-domain optical coherence tomography.
PURPOSE To assess the effect of hemodialysis on retinal and choroidal thicknesses using spectral-domain optical coherence tomography (SD-OCT). METHODS In this prospective interventional study, 25 hemodialysis patients (17 male, 8 female) were enrolled. All participants underwent high-speed, high-resolution SD-OCT (λ=840 mm; 26.000 A-scans/s; 5 µm resolution) before and after hemodialysis. Cho...
متن کاملThe Short-Term Effects of Exercise on Intraocular Pressure, Choroidal Thickness and Axial Length
PURPOSE To explore ocular changes in healthy people after exercise. METHODS Twenty five volunteers underwent exercise for 15 minutes on a treadmill. Measurements of choroidal thickness, intraocular pressure (IOP), ocular biometry, and blood pressure were taken before and after exercise. Enhanced Depth Imaging optical coherence tomography (EDI-OCT) was used to measure choroidal thickness at th...
متن کاملPeripapillary choroidal thickness in healthy Chinese subjects
BACKGROUND To evaluate the peripapillary choroidal thickness of a healthy Chinese population, and to determine its influencing factors. METHODS A total of 76 healthy volunteers (76 eyes) without ophthalmic or systemic symptoms were enrolled. Choroidal scans (360-degree 3.4 mm diameter peripapillary circle scans) were obtained for all eyes using enhanced depth imaging spectral-domain optical c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Retina
دوره 33 1 شماره
صفحات -
تاریخ انتشار 2013