Measuring small compartment dimensions by probing diffusion dynamics via Non-uniform Oscillating-Gradient Spin-Echo (NOGSE) NMR.
نویسندگان
چکیده
Noninvasive measurements of microstructure in materials, cells, and in biological tissues, constitute a unique capability of gradient-assisted NMR. Diffusion-diffraction MR approaches pioneered by Callaghan demonstrated this ability; Oscillating-Gradient Spin-Echo (OGSE) methodologies tackle the demanding gradient amplitudes required for observing diffraction patterns by utilizing constant-frequency oscillating gradient pairs that probe the diffusion spectrum, D(ω). Here we present a new class of diffusion MR experiments, termed Non-uniform Oscillating-Gradient Spin-Echo (NOGSE), which dynamically probe multiple frequencies of the diffusion spectral density at once, thus affording direct microstructural information on the compartment's dimension. The NOGSE methodology applies N constant-amplitude gradient oscillations; N-1 of these oscillations are spaced by a characteristic time x, followed by a single gradient oscillation characterized by a time y, such that the diffusion dynamics is probed while keeping (N-1)x+y≡TNOGSE constant. These constant-time, fixed-gradient-amplitude, multi-frequency attributes render NOGSE particularly useful for probing small compartment dimensions with relatively weak gradients - alleviating difficulties associated with probing D(ω) frequency-by-frequency or with varying relaxation weightings, as in other diffusion-monitoring experiments. Analytical descriptions of the NOGSE signal are given, and the sequence's ability to extract small compartment sizes with a sensitivity towards length to the sixth power, is demonstrated using a microstructural phantom. Excellent agreement between theory and experiments was evidenced even upon applying weak gradient amplitudes. An MR imaging version of NOGSE was also implemented in ex vivo pig spinal cords and mouse brains, affording maps based on compartment sizes. The effects of size distributions on NOGSE are also briefly analyzed.
منابع مشابه
Cellular Size Distributions Revealed by Non-Uniform Oscillating-Gradient Spin-Echo (NOGSE) MRI
Figure 3. NOGSE EPI experiments in the ex-vivo mouse brain. (A-C) Maps of distribution mean, peak, and width, respectively, in images masked for the corpus callosum. (D-F) Maps of distribution mean, peak, and width, respectively, in a coronal image. Notice the strong contrast in the white matter, encompassing a segmentation of the corpus-callosum into its anatomical fiber composition, that reca...
متن کاملSize Distribution Imaging by Non-Uniform Oscillating-Gradient Spin Echo (NOGSE) MRI
Objects making up complex porous systems in Nature usually span a range of sizes. These size distributions play fundamental roles in defining the physicochemical, biophysical and physiological properties of a wide variety of systems - ranging from advanced catalytic materials to Central Nervous System diseases. Accurate and noninvasive measurements of size distributions in opaque, three-dimensi...
متن کاملProbing Internal-Gradient-Distribution-Tensors (IGDT) by Non-Uniform Oscillating-Gradient Spin-Echo (NOGSE) MRI: A New Approach to Map Orientations in Biological Tissues
Target Audience. Scientists interested in orientation mapping. Purpose. Mapping fiber orientations by monitoring internal susceptibility-induced gradient distributions without relying on sample reorientations. Introduction. Orientation mapping plays a central role in functional connectivity studies of the Central-Nervous-System (CNS). Diffusion-Tensor-Imaging (DTI) Susceptibility-Tensor-Imaging...
متن کاملFast and robust measurement of microstructural dimensions using temporal diffusion spectroscopy.
Mapping axon sizes non-invasively is of interest for neuroscientists and may have significant clinical potential because nerve conduction velocity is directly dependent on axon size. Current approaches to measuring axon sizes using diffusion-weighted MRI, e.g. q-space imaging with pulsed gradient spin echo (PGSE) sequences usually require long scan times and high q-values to detect small axons ...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance
دوره 237 شماره
صفحات -
تاریخ انتشار 2013